Special function 4 actual temperature display 46, Programming special functions, Special function 4 actual temperature display – Miele PROFESSIONAL PG 8050I User Manual
Page 46
Special function 4
Actual temperature display
It is not possible to change settings
while a program is running. You will
have to cancel the program. The
"Start/Stop" indicator must be
flashing.
The actual temperature can be
displayed constantly or only during the
program blocks "Wash" and "Rinse".
Accessing the programming level
^ Turn the dishwasher off with the
"On/Off" button.
^ Press and hold the "Extra drying"
and "Start/Stop" buttons, at the same
time, turn the dishwasher on with the
"On/Off" button.
^ Release the buttons.
The "Wash" indicator will come on and
the "Recharge" indicator will flash.
If they do not come on, restart the
procedure.
The set water hardness will then appear
in the display.
^ Press the "Extra drying" button twice.
Special function 1 "Rinse aid
temperature increased" is displayed in
double digits (
10 or 11).
^ Press the % button until 40 or 41
appears in the display.
The "Spray arm" indicator will come on,
the "Glasses" (G 8050 ) / the "China &
Crystal" (PG 8050i) program indicator
will come on or flash, the "Recharge"
indicator will flash.
Special function 4 "Actual temperature
display" is selected and indicated with
two-digit numbers in the display.
Programming special functions
46