beautypg.com

Installation checklist, Seawater cooling system, Mounting – Mars Air Systems L-2254 User Manual

Page 9: Electrical, Grilles and ducting

background image

9

English

L-2254 Installation

Installation Checklist

(Review prior to installation)

Note: Refer to the Elite and Passport I/O manuals
for installation and operation of those digital
controls.

Seawater Cooling System

❑ Speed scoop located as far below the water line and

as close to the keel as possible

❑ Shut off valve (sea cock) and speed scoop properly

sealed and tight

❑ Seawater pump is at least one foot below water line

and securely mounted

❑ Strainer mounted below pump with access to filter

❑ Double/reversed stainless steel hose clamps on all

hose connections

❑ Teflon tape on all threaded connections

❑ Hose runs uphill from speed scoop and sea cock to

strainer, pump and a/c unit, then downhill (if possible)
from a/c unit to overboard discharge

❑ Water flowing freely from overboard discharge while

pump is running

❑ Pump relay panel, if used, must have its own circuit

breaker sized for the pump (20 amp max)

❑ All metal fittings should be bonded

Mounting

❑ Not in engine room or bilge areas, must be sealed

away from exhaust or fumes

❑ Proper spacing allowed around unit

❑ Attached to solid level platform with hold down clips

provided

❑ Condensate drain routed aft and down hill to a sealed

sump (not bilge)

❑ Blower rotated toward supply air grille

Electrical

❑ The wiring diagram is located in the electrical box. If

that diagram is damaged or if you need a copy, please
call Dometic with the unit part number, serial number,
and wiring diagram number, all of which are located on
the unit data plate.

❑ All butt connections on pumps wire tightly crimped and

heat shrunk

❑ AC power source installed and grounded/bonded in

accordance with ABYC standards

❑ Control wires connected to terminal strip with captive

fork or ring terminals

❑ Circuit breakers sized according to specifications on

the data plate label

❑ Digital display cable is connected at both ends

❑ Pump Relay Panel (if used) has a dedicated circuit

breaker sized for the pump but not to exceed 20 amps
maximum.

Grilles and Ducting

❑ Supply air grille mounted as high as possible

❑ Return air grille mounted as low and as close to the

a/c unit as possible

❑ Return air grille mounted away from bilge vapors or

exhaust fumes

❑ Ducting is pulled taut, straight, smooth and properly

connected with no excess