Practical examples -6, Practical examples – Moxa Technologies 2140 User Manual
Page 68

%s
second
%t
tenth
second
Practical Examples
Command line
Description
MAB=1C;
When any motion is detected on channel 1 or 2, “Normal
Close” of relay output 1 will short with “Common”.
1H*2\=(5)1O;
When DI1 high companied with DI2 transient from high
to low, “Normal Open” of relay output 1 will short with
COMMON in 5 seconds.
B\+C\+D\=W{192.168.0.1:6000}{no
signal!};
If there is no signal on channel 2 or 3 or 4, a message “no
signal!” will be sent to port 6000 of 192.168.0.1 once.
1H=VAP14;
When sensor input 1 is high, drive the camera mapped to
video 1 to go to preset location 15.
MCD=UF+SABCD+N{video%c%a@
%y%M%d%h%m%s};
If any motion is detected on channel 3 or 4, upload
snapshots taken on channel 1, 2, 3 and 4. If an event
triggered at 19:05:30 2002/10/15, the snapshot files will
be named as,
[email protected],
[email protected]
[email protected],
[email protected]
[email protected],
[email protected]
[email protected],
[email protected]
[email protected],
[email protected]
[email protected],
[email protected]
The script file is limited to a maximum of 500 characters. The actual performance will depend
on the complexity of the command script.
VPort 2140 User’s Manual
5-6