Moxa Technologies CP-102U/UL User Manual

Page 53

background image

CP-102U/UL User’s Manual

Software Installation

3-41

NOTE

The driver configuration will NOT take effect until you restart the PC.

Using Event Log

Once the system restarts, you may check the event log recorded by the MOXA driver to verify that
the board’s ports have been initialized successfully.

To view the event log, enter the Administrative group, click the Event Viewer icon, and then
select Log and System to check a message similar to “MOXA CP-102U/UL board, with first serial
port COM3, has been enabled” for each newly configured board.

NOTE

If an error message similar to “Cannot find any configured MOXA Smartio/Industio series
board!” pops up, refer to the Troubleshooting chapter for possible solutions.

Removing a CP-102U/UL Board

To remove a CP-102U/UL board, first shut down your PC, and then physically remove the board
from the PCI or PCI-X slot. The next time you start up the PC, the system will automatically
remove the configuration for the board. You do not need to click the Remove button in the Moxa
Smartio/Industio Configuration Panel
.