Microsoft STOREXPRESS DSE4XM1 User Manual
Page 45

March 10, 2009
Dolphin Interconnect Solutions
45
www.dolphinics.com
Sample Output
The fio-status command alone displays abbreviated information on all installed
ioDrives:
fio-status
Found 2 ioDrives in this system.
Fusion-io driver version: 1.2.4.3
fct0 Attached
ioDimm3 SN:0719 Firmware v11791
92 GBytes unformatted capacity.
fct1 Not attached
ioDimm3 SN:0299 Firmware v11791
154 GBytes unformatted capacity.
The fio-status command with the –a parameter and no device name displays all the
information available on every installed ioDrive.
fio-status -a
Found 2 ioDrives in this system.
Fusion-io driver version: 1.2.4.3
fct0 Attached
-c
Count: Report only the number of ioDrives installed.
-a
All: Print all available information for each device. The fio-status
command displays the following information:
•
Serial number
•
Part number
•
Manufacturer's name
•
Manufacturing date
•
Firmware version at manufacturing time
•
Size of the device, out of total capacity
•
NAND manufacturer
•
NAND cell type (SLC, MLC, or
unknown)
•
Size of the device in blocks
•
Size of a block in pages
•
Size of a page in bytes (including ECC
overhead)
•
Number of pads, planes and banks
•
Size of an ECC-protected unit (includ-
ing check-bit overhead)
•
FPGA ID
•
Hardware UID
•
Bus ID
•
Vendor ID
•
Subsystem vendor and device IDs
•
Device ID
•
PCI slot number
•
Internal temperature (avg. and max.,
since driver load) in degrees Centigrade
•
Ambient temperature, in degrees Centi-
grade
•
Internal voltage: avg. and max.
•
Auxiliary voltage: avg. and max.
•
Health status: Healthy, Marginal, or
Degraded, based on the percentage of
good erase blocks on the device
•
Percentage of good data
•
Percentage of good blocks
•
Percentage of good metadata