Installation, Figure. 1 position drapery near heater, Figure. 2 – Marley Engineered Products C1800 User Manual
Page 2: Followed by wc or nwc suffix
This Heater is designed to provide years of efficient, trouble free
operation as a primary or supplementary heat source for residen-
tial and commercial applications. Baseboard heaters must be
thermostatically controlled for efficient, safe operation. A thermo-
stat is not provided with this heater. However, a single or double
pole thermostat accessory is available for installation into this
heater at your place of purchase, or the heater may be connect-
ed to any suitable wall mounted thermostat that will meet the elec-
trical load requirements. Installation or use of this product in any
manner not described herein will void the warranty and could
result in injury, damage to property, or permanent damage to
heater.
UNPACKING HEATER
Check heater to make sure it has not been damaged in shipping.
Do not install or attempt to operate the heater if damaged. Return
to place of purchase or file claim with freight carrier.
NOTICE TO OWNERS
Certain fabrics discolor in time from indirect sunlight and normal
room temperature - mostly organic and synthetic material. They
will discolor more rapidly when exposed to direct sunlight and
warm currents. Hang drapes to provide minimum of 2 in.(51mm)
air space between heater front and nearest drape fold as shown
in Example 1 Figure 1, or 6 in.(153mm) airspace between top of
heater and bottom of drapes as shown in Example 2, Figure 1.
Allow minimum clearance of 1 in. (26mm) from drapes to ceiling
and to top of floor covering to permit air circulation as shown in
Example 1, Figure 1.
INSTALLATION
FLOORS & CARPETING:
Heaters may be mounted directly on any floor surface, including
carpeting. Where wall-to-wall carpets are installed after the base-
board installation, the carpeting can be run up to the front and
around the heater body, providing it does not obstruct air flow.
(Maximum 3/4” (19mm) thick).
1.
Remove wiring compartment cover at end of heater where
power supply cable is to enter. Determine desired mounting
location (Figure 2), position heater to wall as intended and mark
wall (or floor) at location where power supply is to enter heater.
Heater Ampere Rating.
Total Amps
Minimum
AWG. Wire Size
(Copper)
Circuit Breaker
or Fuse Size
0 thru 12
12.1 thru 16
16.1 thru 24
#14
#12
#10
15 amp
20 amp
30 amp
NET VOLUMES OF WIRING COMPARTMENT
DESCRIPTION
CUBIC
INCHES
CUBIC
CENTIMETERS
Heater Only (Each Wiring Compartment)
Heater W/SP Thermostat
Heater W/DP Thermostat
Heater W/Heat-Cool Switch Receptacle
Heater W/Duplex Receptacle
Heater W/DP Disconnect Switch
Heater W/Power Relay
Heater W/Transformer Relay
14.96
11.18
11.18
9.51
11.18
11.18
10.76
2.93
241
180
180
153
180
180
174
47
Figure. 1 Position Drapery near Heater
2
Figure. 2
Residential
Model No.
2512 *
25126 *
2513 *
2514 *
2515 *
2516 *
2502 *
25026 *
2503 *
2504 *
2505 *
2506 *
2507 *
2508 *
25008 *
2542 *
25426 *
2543 *
2544 *
2545 *
2546 *
2547 *
2548 *
25408 *
2572 *
25726 *
2573 *
2574 *
2575 *
2576 *
2577 *
2578 *
25708 *
25326 *
2533 *
2534 *
2535 *
2536 *
2537 *
2538 *
25308 *
2530 *
2564 *
2565 *
2566 *
2567 *
2568 *
25608 *
2560 *
-
C25126 *
C2513 *
C2514 *
C2515 *
C2516 *
-
C25026 *
C2503 *
C2504 *
C2505 *
C2506 *
C2507 *
C2508 *
C25008 *
-
C25426 *
C2543 *
C2544 *
C2545 *
C2546 *
C2547 *
C2548 *
C25408 *
-
C25726 *
C2573 *
C2574 *
C2575 *
C2576 *
C2577 *
C2578 *
C25708 *
C25326 *
C2533 *
C2534 *
C2535 *
C2536 *
C2537 *
C2538 *
C25308 *
C2530 *
C2564 *
C2565 *
C2566 *
C2567 *
C2568 *
C25608 *
C2560 *
3.3
4.2
6.3
8.3
10.4
12.5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.9
2.4
3.6
4.8
6.0
7.2
9.6
8.4
12.0
1.4
1.8
2.7
3.6
4.5
5.4
6.3
7.2
8.7
1.1
1.4
2.0
2.7
3.4
4.1
4.7
5.4
6.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.7
2.1
3.1
4.2
5.2
6.3
7.3
8.3
10.4
1.2
1.6
2.4
3.1
3.9
4.7
5.5
6.3
7.5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.4
1.8
2.7
3.6
4.5
5.4
6.3
7.2
9.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Commercial
Model No.
120
Volt
208 Volt 240 Volt 277 Volt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.4
2.2
2.9
3.6
4.3
5.0
5.8
7.2
7.2
-
-
-
-
-
-
-
347 Volt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.7
2.1
2.5
2.9
3.3
4.2
4.2
600 Volt
* Followed by WC or NWC suffix