Pilot must be lit and the valve control knob turned to the “ON” position. Meter leads must be connected to
the TP and the TH/TP terminals on the control valve.
• Turn RS-ON-OFF switch to the “ON” position.
9 If meter is reading more than 175 millivolt and the main burner does not come on, then replace
control valve.
9 If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this
manual to determine the cause of the low reading.
• Turn RS-ON-OFF switch to the “RS ” position and wall switch to “ON”
9 If meter is reading more than 175 millivolt and the main burner does not come on, then replace
control valve.
9 If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this
manual to determine the cause of the low reading.
Electronic Pilot Ignition Wiring:
WARNING
Do not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction or be destroyed.
Figure 14: Wiring Diagram for Electronic Ignition System
Remote Wall Switch
Position the wall switch. Refer to Figure 14: Wiring Diagram for Electronic Ignition System. Do not
extend beyond the 15 feet of wire.