beautypg.com

Minuteman UPS ALLIANCE SERIES User Manual

Page 6

background image

4



Input Voltage (AC Mode Function)

95-135 VAC (w/ boost)

120 VAC Models

102-135 VAC (w/o boost)

175-260 VAC (w/ boost)

220 VAC Models

190-260 VAC (w/o boost)

Boost Capability (AC Mode Function)

+ 12 %

5VAC per SW, (120VAC models)

Transfer Voltage Adjustment

10VAC per SW (220VAC models)

Transfer Time

2 msec typical

Input Frequency Deviation for Synchronization

± 10 %

Inrush Current

1.5x rated

Surge Protection

3 way, meets IEEE STD. 587

RFI/EMI Filtering

Both Common and Normal Modes

Inverter mode (Backup Operation)

Synchronized Simulated

Waveform

Sinewave Approximation

Crest Factor (Non-Linear Load)

3:1

Overload Capacity (50 msec Maximum)

3x rated

Voltage Regulation

± 5%

Frequency Regulation

± 1%

DC-to-AC Efficiency (Full Load)

75%

Overload/Short Circuit Protection

Electronic and Fused

Discharged Battery Recharge Time

8 hours (95% of full charge)

Run Time

See Chart