Minuteman UPS ALLIANCE SERIES User Manual
Page 13
11
FUSE REPLACEMENT
(All Models except A2000
)
A300, A300/2, A425, A425/2, A900 and A1250 models: Turn off the UPS and unplug the power
cord from the wall receptacle before removing the fuse cap. Remove and inspect the fuse and
replace, if blown.
Other models: turn off the UPS and unplug the power cord plug from the UPS IEC 320 socket.
Locate the fuse drawer opening and insert a flat-blade screwdriver into the opening, pry the drawer
outward and remove it from the IEC 320 socket. Inspect the active fuse and replace, if blown.
NOTE: Replacement fuses can be obtained from Para Systems or any electronic parts distributor
who stocks Bussman or Littlefuse fuses.
POLICY AND INSTRUCTION
FOR RETURN OF PRODUCT TO PARA SYSTEMS
Call Technical Support if you experience any problems with MINUTEMAN ALLIANCE Units.
1. If you wish to file a Platinum Protection Plan claim, request a claims packet from the
Technical Support Representative.
2. If a UPS unit must be returned to Para Systems for any other reason:
a. Describe the problem or reason for the return and you will be given a Return Material
Authorization Number (RMA #). This number must be placed on the shipping carton,
preferably on the return shipping label. The RMA # on the carton will ensure prompt
handling when received at Para Systems, Inc.
b. Pack the UPS for shipment in the original carton and foam. Other packaging methods
can result in damage to the UPS.
c. Be sure to enclose the name and telephone number of the person who can authorize
repair charges. Also, include the address for product return.
d. Send the UPS freight prepaid to Para Systems headquarters. C.O.D. shipments will
not be accepted.
e. If repair is Para Systems' responsibility, per the warranty statement, there will be no
repair charge. The UPS will be repaired and returned freight prepaid, provided the
UPS was returned in the original shipping carton and foam. If other packing methods
used result in shipping damage, this repair will be at your expense. If the packaging is
not deemed usable for UPS return, there will be a charge for the cost of a new box and
foam.
f.
If UPS repair is not Para Systems' responsibility, you will be advised of the estimated
repair charges by telephone for your authorization. Should you choose not to have the
UPS repaired, there will be a repair estimate charge of $40. The UPS will be returned
C.O.D. for either the repair amount or estimate plus shipping and handling.