beautypg.com

Meridian America DSP5000 User Manual

Page 60

background image

Appendix

60

DSP5000 User Guide

Controls

Test mode

Remote key

Logo

Input on
DSP5000

Control?

Channel
selected

CD

1L

D1

No

Left

Radio

1r

D1

No

Right

LP

2L

D2

No

Left

Tape 1

2r

D2

No

Right

Internally generated test signals

A number of internally generated test signals are available in Calibrate
mode. These include:

one sample width impulse with 2Hz repetition rate

four sample width impulse with 2Hz repetition rate

pink noise

To switch from the input to the test signals:

1. Press the

w

or

e

menu key until you see a display like this:

OFF

indicating that signal generation is off.

2. Press the

n

or

s

menu key to move between a narrow impulse, a

wide impulse and pink noise, with these displays:

thin

FAt

PIn.

To set the relative level of the tweeter:

1. Press the

w

or

e

menu key until you see a display like this:

G.

0.0

indicating a relative setting of 0.0dB

2. Press the

n

or

s

menu key to move in 0.5dB steps over the range

±3.5dB

Getting out of Calibrate

Once calibration is compete, switch the DSP5000 off and then on again
while pressing Clear.

This should bring you back into the normal playing state.