beautypg.com

Split return, Figure 6 split return configuration, Sg4-drt-2x installation sheet – Motorola SG4-DRT-2X User Manual

Page 6: 6starline

background image

6

STARLINE

Split Return

In the split return configuration, each pair of RF returns is applied to a separate 2X redundant
return configuration board. In a typical installation, the RF modules in Ports 1 and 3 are
connected to the 2X redundant return board in return configuration location 2. The RF modules
in Ports 4 and 6 are connected to the 2X redundant return configuration board in configuration
location 3. The 2X redundant return configuration board, in location 2, directs RF to CH B of the
SG4-DRT-2X. The 2X redundant return configuration board, in location 3, directs RF to CH A of
the SG4-DRT-2X. The same configuration board is used in the split redundant return
configuration explained in the next subsection.

Figure 6 illustrates the split return configuration:

Figure 6
Split return configuration

2X DIGITAL TRANSMITT ER

CH B

CH A

-5 dBmV

NOMINAL

TOTAL POWER

-5 V/mW

ENABLE/FAULT

-5 dBmV

NOMINAL

TOTAL POWER

J

X
P

J

X
P

A / D

A / D

INVISIBLE LASER

RADIATION. AVOID

EXPOSURE TO BEAM.

CLASS 3B LASER

PRODUCT.

Port 1

Port 6

Split Return

Configuration board

location #2

Split Return

Configuration board

location #3

CH A

CH B

Port 3

Port 4

SG4-DRT-2X Installation Sheet