beautypg.com

Figure 13 segmented return board, Figure 14 segmented return board – signal flow, Sg4-drt-2x installation sheet – Motorola SG4-DRT-2X User Manual

Page 13

background image

STARLINE 13

Figure 13 illustrates the segmented return plug-in board.

Figure 13
Segmented return board

TX1

SM

TX2

R1

J3

J5

R4

R7

R6

R9

R8

J7

J4

IN2

IN1

R5

R2

R3

T1

R10

J6

C1

2

C

12

C1

1

C7

C9

C1

0

C6

C8

C3

C2

C1

R1

1

Figure 14 illustrates the signal flow through the segmented return board:

Figure 14
Segmented return board – signal flow

-0.5dB

Loss = 0.9 dB

TX1

TX2

IN2

IN1

SM

Pad

Pad

To set up the segmented return option:

1

Confirm that dual SG4-DRT-2X return transmitters are installed in lid optics slots 3 and 4
and 5 and 6.

2

Confirm that a segmented return board is installed in the return configuration locations 2
and 3 as illustrated in Figure 11.

3

Connect an RF cable from connector TX1 on the segmented return board in configuration
location 2 to CH B of the SG4-DRT-2X in lid optics slots 3 and 4.

4

Connect an RF cable from connector TX2 on the segmented return board in configuration
location 2 to CH A of the SG4-DRT-2X in lid optics slots 3 and 4.

5

Connect an RF cable from connector TX1 on the segmented return board in configuration
location 3 to CH B of the SG4-DRT-2X in lid optics slots 5 and 6.

6

Connect an RF cable from connector TX2 on the segmented return board in configuration
location 3 to CH A of the SG4-DRT-2X in lid optics slots 5 and 6.

The RF cable should be approximately eight inches long and have red boots on the connector
signifying the return path.

7

If necessary, connect the appropriate return RF cables from the SG4-RF modules to each
segmented return board.

8

Ensure that the PIC cable is properly connected to the lid and power distribution board in
the housing base.

SG4-DRT-2X Installation Sheet