DCA10SPX4/DCA10SPXU4 — SETUP

Refueling Procedure:

1. Level Tanks – Make sure fuel cells are level with the

ground. Failure to do so will cause fuel to spill from the
tank before reaching full capacity (Figure 14).

Figure 14. Only Fill on Level Ground

ONLY! use

#2 diesel fuel when

refueling.

NOTE

3.

NEVER overfill fuel tank – It is important to read the
fuel guage when filling trailer fuel tank. DO NOT wait for
fuel to rise in filler neck.

Figure 17. Fuel Expansion

2. Remove fuel cap (internal fuel tank) and fill fuel tank as

shown Figure 15.

ALWAYS place trailer on firm level ground before refueling
to prevent spilling and maximize the amount of fuel that
can be pumped into the tank.

CAUTION - REFUELING THE GENERATOR

Diesel fuel and its vapors are dangerous
to your health and the surrounding
environment. Avoid skin contact and/or
inhaling fumes.

WARNING - RESPIRATORY HAZARDS

DO NOT OVER-FILL fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 17).

CAUTION - REFUELING THE GENERATOR

Figure 15. Fueling the Generator

If generator is equipped with an
environmental fuel tank, refer-

ence Figures 16 and 17.

NOTE

Figure 16. Full Fuel Tank