3
Serial Converters and Repeaters
TCC-100
TCC-100-T
TCC-100I
TCC-100I-T
TCC-80
TCC-80I
TCC-120
TCC-120I
TCC-82
RS-232 Side
Connector
DB9 female
DB9 female
---
---
---
Signals
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
(Loop-back wiring: RTS to CTS, DTR to
DSR and DCD)
---
---
---
RS-422/485 Side
Connector
Terminal Block
Terminal Block or DB9 male
---
---
---
Signals
(interface selected by DIP switch)
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w Signals: Data+, Data-, GND
(interface selected by DIP switch)
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w Signals: Data+, Data-, GND
---
---
---
RS-485 Data Direction
Control
---
---
ADDC®
---
---
---
Serial Communication
Connectors
---
---
---
---
Terminal Block on both ends
DB9 male/female
Baudrate
50 bps to 921�6 Kbps
50 bps to 921�6 Kbps
50 bps to 921�6 Kbps
50 bps to 921�6 Kbps
Signals
---
---
---
---
RS-422/485-4w: TxD+, TxD-, RxD+, RxD-
RS-485-2w: Data+, Data-
RS-232: TxD, RxD,
RTS, CTS
(Loop-back wiring:
DTR to DSR and DCD)
RS-485 Data Direction
Control
---
---
---
---
ADDC®
Pull High Resistance
150K ohm or 1K ohm (default)
Pull Low Resistance
ESD Protection
15 KV
15 KV
15 KV for all signals
15 KV for all signals
Optical Isolation
---
2 KV
---
2�5 KV rms for 1
minute
---
2 KV for power and
signal
4 KV for 1 minute
Physical Characteristics
Housing
Aluminum
ABS + PC
Aluminum
ABS
Dimensions (mm)
67 x 100�4 x 22 mm
42 x 80 x 22 mm
67 x 100�4 x 22 mm
42 x 80 x 23�6 mm
Weight
148 ± 5 g
50 ± 5 g
148 ± 5 g
60 ± 5 g
Environmental Limits
Operating Temperature
-20 to 60°C, or -40 to 85°C
0 to 60°C
-20 to 60°C
0 to 60°C
Operating Humidity
5 to 95% RH
5 to 95% RH
5 to 95% RH
5 to 95% RH
Storage Temperature
-20 to 85°C
-20 to 75°C
-20 to 85°C
-20 to 75°C
Power Requirements
Source of Input Power
Power input jack
RS-232 port (TxD, RTS, DTR) or power
input jack
RS-232 port (TxD signal) or power input jack
RS-232 port (TxD
signal) or power input
jack
Input Voltage
12 to 48 VDC
5 to 12 VDC
12 to 48 VDC
5 to 12 VDC
Power Consumption
300 mA @ 12 V
400 mA @ 12 V
10 mA @ 5 V
(with termination
disabled)
20 mA @ 5 V
(with termination
disabled)
98 mA @ 12 V, 1�18 W
234 mA @ 12 V, 2�81 W
20 mA @ 5 V
Connection
---
---
---
---
---
---
---
Overload Current
Protection
---
---
---
---
---
---
---
Reverse Polarity Protec-
tion
---
---
---
---
---
---
---
Burst Protection (EFT)
---
---
---
---
---
---
---
Surge Protection
---
---
---
---
---
---
---
Voltage Reversal
Protection
Protects against V+/V- reversal
---
---
Protects against V+/V- reversal
---
Over Current Protection
√
√
---
---
√
√
---
Regulatory Approvals
CE
Class B
Class B
Class B
Class B
FCC
Class B
Class B
Class B
Class B
Reliability
Warranty
5 years (see www�moxa�com/warranty)