Chassis media converters, Industrial networking solutions, Media converters > chassis media converters – Moxa Technologies MOXA V91 User Manual
Page 63

Industrial Networking Solutions
i n f o @ m o x a . c o m
w w w. m o x a . c o m
53
Media Converters
>
Chassis Media Converters
3
Chassis Media Converters
TRC-190-AC
TRC-190-DC
TCF-142-M-SC-RM
TCF-142-M-ST-RM
TCF-142-S-SC-RM
TCF-142-S-ST-RM
Optical Fiber Side
Fiber Connector
---
SC or ST
SC or ST
Cables Requirements
---
50/125, 62�5/125, or 100/140 µm
8�3/125, 8�7/125, 9/125, or 10/125 µm
Transmission Distance
---
5 km
40 km
Wavelength
---
850 nm
1310 nm
Tx Output
---
> -5 dBm
> -5 dBm
Rx Sensitivity
---
-20 dBm
-25 dBm
Point-to-Point
Transmission
---
Point-to-Point Transmission: Half-duplex or full-duplex
Point-to-Point Transmission: Half-duplex or
full-duplex
RS-232/422/485 Side
Connector
---
Terminal Block
RS-232 Signals
---
TxD, RxD, SGND
RS-422 Signals
---
TxD+, TxD-, RxD+, RxD-, SGND
RS-485-4w Signals
---
TxD+, TxD-, RxD+, RxD-, SGND
RS-485-2w Signals
---
Data+, Data-, SGND
Baudrate
---
50 bps to 921�6 Kbps
ESD Protection
---
15 KV
15 KV
Physical Characteristics
Housing
SECC (1�2 mm)
SPCC
SPCC
Dimensions (mm)
440 x 260 x 77 mm
86�8 x 136�5 x 21 mm
86�8 x 136�5 x 21 mm
Weight
5�2 kg (11�4 lbs), with one power module installed
---
---
Installation
---
---
---
Number of Slots
19 slots in the front for slide-in modules, 2 slots in the
back for power supply modules
---
---
Environmental Limits
Operating Temperature
0 to 60°C
0 to 60°C
0 to 60°C
Operating Humidity
5 to 95% RH
5 to 95% RH
5 to 95% RH
Storage Temperature
-20 to 75°C
-20 to 75°C
-20 to 75°C
Power Requirements
Input Voltage
Universal 100 to 240 VAC (47 to 63 Hz)
12 VDC
12 VDC
Power Consumption
5�4 A @ 12 V (max� output) or
12 to 48 VDC
150 mA @ 12 V
150 mA @ 12 V
Regulatory Approvals
CE
Class B
Class B
FCC
Part 15 sub part B Class A
Part 15 sub part B Class A
EMI
EN55022 1998, Class B
---
---
EMS
EN61000-4-2 (ESD), Criteria A, Level 4
EN61000-4-3 (RS), Criteria A, Level 2
EN61000-4-4 (EFT), Criteria A, Level 3
EN61000-4-5 (Surge), Criteria A, Level 3
EN61000-4-6 (CS), Criteria A, Level 2
EN61000-4-8 (PFMF), Criteria A, Level 3
EN61000-4-11 (DIPS), Criteria A
EN61000-4-2 (ESD), Criteria A, Level 4
EN61000-4-3 (RS), Criteria A, Level 2
EN61000-4-4 (EFT), Criteria A, Level 3
EN61000-4-5 (Surge), Criteria A, Level 3
EN61000-4-6 (CS), Criteria A, Level 2
EN61000-4-8 (PFMF), Criteria A, Level 3
Freefall
---
IEC 60068-2-32
Reliability
Warranty
5 years (see www�moxa�com/warranty)