Serial-to-Fiber Media Converters
3
Serial-to-Fiber Media Converters
ICF-1150-M-SC/ST
ICF-1150-M-SC/ST-T
ICF-1150I-M-SC/ST
ICF-1150I-M-SC/ST-T
ICF-1150-S-SC/ST
ICF-1150-S-SC/ST-T
ICF-1150I-S-SC/ST
ICF-1150I-S-SC/ST-T
TCF-142-M-SC/ST
TCF-142-M-SC/ST-T
TCF-142-S-SC/ST
TCF-142-S-SC/ST-T
TCF-90-M/S
Optical Fiber Side
Fiber Connector
SC or ST
SC or ST
SC or ST
SC or ST
SC or ST
ST
Cables Requirements
Single-mode: 8�3/125, 8�7/125, 9/125, or 10/125 µm
Multi-mode: 50/125, 62�5/125, or 100/140 µm
Transmission Distance
Single-mode: 40 km
Multi-mode: 5 km
Wavelength
Single-mode: 1310 nm
Multi-mode: 850 nm
Tx Output
Single-mode: > -5 dBm
Multi-mode: > -5 dBm
Rx Sensitivity
Single-mode: -25 dBm
Multi-mode: -20 dBm
Point-to-Point
Transmission
Half-duplex or full-duplex
---
Multi-drop
Transmission
Half-duplex, fiber ring
---
Ring Transmission
---
---
---
---
Half-duplex
---
RS-232 Side
Connector
---
---
---
---
---
---
DB9 female
Signals
---
---
---
---
---
---
Tx, Rx, GND (Loop-back
wiring: RTS to CTS,
DTR to DSR and DCD)
Baudrate
---
---
---
---
---
---
300 bps to 115�2 Kbps
RS-232/422/485 Side
Connector
---
---
---
---
Terminal Block
---
RS-232 Signals
TxD, RxD, SGND
---
RS-422 Signals
TxD+, TxD-, RxD+, RxD-, SGND
---
RS-485-4w Signals
TxD+, TxD-, RxD+, RxD-, SGND
---
RS-485-2w Signals
Data+, Data-, SGND
---
Baudrate
50 bps to 921�6 Kbps
---
ESD Protection
15 KV for all signals
---
Isolation
2 KV RMS isolation per I/O port for 1 minute
---
---
---
Physical Characteristics
Housing
Aluminum (1 mm)
ABS + PC
Dimensions (mm)
30�3 x 70 x 115
67 x 100 x 22 mm
42 x 80 x 22 mm
Environmental Limits
Operating Temperature
0 to 60°C or -40 to 85°C
0 to 60°C
Operating Humidity
5 to 95% RH
5 to 95% RH
Storage Temperature
-40 to 85°C
-20 to 75°C
Power Requirements
Source of Input Power
---
---
---
---
---
---
RS-232 port (TxD
signal) or power input
jack
Input Voltage
12 to 48 VDC
12 to 48 VDC
12 to 48 VDC
Power Consumption
127 mA @ 12 V
163 mA @ 12 V
140 mA @ 12 V
20 mA @ 5 V (with
termination disabled)
Burst Protection (EFT)
4 KV
2 KV
---
Surge Protection
2 KV
2 KV
---
Voltage Reversal
Protection
Protects against V+/V- reversal
Protects against V+/V- reversal
---
Over Current Protection
1�1 A
1�1 A
---
Regulatory Approvals
CE
Class B
---
---
Class B
FCC
Part 15 sub Class B
Part 15 Subclass B
Class B
Safety
UL 508
---
---
---
UL/CUL
---
UL60950-1
---
EMI
EN55022 1998, Class B
EN55022 1998, Class B
---
EMS
EN61000-4-2 (ESD), Criteria A, Level 4
EN61000-4-3 (RS), Criteria A, Level 3
EN61000-4-4 (EFT), Criteria A, Level 4
EN61000-4-5 (Surge), Criteria A, Level 3
EN61000-4-6 (CS), Criteria A, Level 3
EN61000-4-8 (PFMF), Criteria A, Level 5
EN61000-4-2 (ESD), Criteria A, Level 3
EN61000-4-3 (RS), Criteria A, Level 2
EN61000-4-4 (EFT), Criteria A, Level 2
EN61000-4-5 (Surge), Criteria A, Level 3
EN61000-4-6 (CS), Criteria A, Level 2
EN61000-4-8 (SFMF), Criteria A, Level 1
---
ATEX
Class 1, Zone 2, EEx nC IIC (pending)
---
---
---
Hazardous Location
UL/cUL Class 1, Div� 2, Group A, B, C and D (Pending)
---
---
---
TÜV
EN 60950-1
EN60950-1
---
Freefall
IEC 60068-2-32
---
---
---
Water and Dust Proof
IP30
---
---
---
Reliability
Warranty
5 years (see www�moxa�com/warranty)