6. If the engine has started, slowly return the choke lever

(Figure 13 ) to the

“OPEN”

position. If the engine has not

started repeat steps 1 through 6.

7. Before the generator is placed into operation, run the engine

for 3-5 minutes. Check for abnormal smells, fuel leaks, and
noises that would associate with lose components.

8.

Place the idle control switch (Figure 13) in the "OFF"
(down) position. This will allow the engine speed to run
at speed about 3600 RPM's

10. If desired, verify with a voltmeter (Figure16) that 120

VAC is present at the GFCI duplex receptacle.

Figure 16. 120 VAC GFCI Receptacle

NOTE

Placing the

idle control switch

in

the RUN position (Figure 14) allows
the engine to operate at a maximum
speed of about 3600 RPM's. When
the idle control switch is placed in
the up position (ON), the generator

will run at idle speed (2200 RPM's) until a load is applied, at that
time the engine speed will increase to 3600 RPM's as long as
the load is being applied. When the load is not in use, the engine
speed will drop back to the idle mode after about 3 seconds.

GAW-135H — INITIAL START-UP/GENERATOR OPERATION

Figure 13. Idle Control Switch (Off)

Figure 14. Idle Control Switch (On)

Connecting the Load

1. If small wattage power tools are required, connect them

to the GFCI receptacle.

9. Place the main circuit breaker (Figure 15) in the ON

position.

Figure 15. Main Circuit Breaker (ON)