Overload protection (honda-powered units), Adjusting engine speed (kohler-powered units), 3. overload protection (honda-powered units) – Miller Electric Blue Star 6000 User Manual
Page 30: 4. adjusting engine speed (kohler-powered units)

OM-499 Page 26
Return To Table Of Contents
8-3.
Overload Protection (Honda-Powered Units)
1
Ignition Circuit Breaker
(Electric-Start Models Only)
The circuit breaker protects the en-
gine battery charging circuit. A
short circuit or a battery connected
in reverse polarity will trip the circuit
breaker.
Press button to reset breaker.
.
If a switch or breaker opens, it
usually indicates a more seri-
ous problem exists. Contact a
Factory Authorized Service
Agent.
1
Ref. 802 094-A
3
1
2
8-4.
Adjusting Engine Speed (Kohler-Powered Units)
802 511-A / Kohler Dwg.
After tuning engine, check engine
speeds. See table for proper no
load speeds. If necessary, adjust
speeds as follows:
Start engine and run until warm.
Weld/Power Speed
Adjustment
1
Throttle Control Lever
2
Adjustment Screw
Move lever to Run (far right) posi-
tion. To increase speed, turn screw
out (counterclockwise) while lightly
pushing lever to the right. To de-
crease speed, turn screw in (clock-
wise).
Idle Speed Adjustment
3
Adjustment Screw
Move lever to idle (far left) position.
To increase idle speed, turn screw
in (clockwise). To decrease idle
speed, turn screw out (counter-
clockwise).
Y
Stop engine. Close fuel
valve.
Tools Needed:
2000
±
150 rpm
3720
±
50 rpm (60 Hz)
3250
±
50 rpm (50 Hz)
Top View
Top View