Section 5 − installation, Installing welding generator, Grounding generator to truck or trailer frame – Miller Electric Blue Star 6000 User Manual
Page 18: 1. installing welding generator, 2. grounding generator to truck or trailer frame

OM-499 Page 14
Return To Table Of Contents
SECTION 5 − INSTALLATION
5-1.
Installing Welding Generator
install1 10/00*− 802 524-A / Ref. 151 556 / 158 936-A / S-0854
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Airflow Clearance
Location
Y
Always securely fasten welding
generator onto transport vehicle
or trailer and comply with all DOT
and other applicable codes.
5-2.
Grounding Generator To Truck Or Trailer Frame
install1 10/00* − Ref. 151 556 / S-0854
Y
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y
If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.
1
2
Electrically bond generator frame to
vehicle frame by metal-to-metal con-
tact.
GND/PE
3
4
2
OR