Routine maintenance, 2. routine maintenance, 8 h 20 h – Miller Electric Blue Star 6000 User Manual
Page 29: 50 h, 100 h, 200 h, 300 h, 500 h, 1000 h

OM-499 Page 25
Return To Table Of Contents
8-2.
Routine Maintenance
Recycle
engine
fluids.
Y
Stop engine before maintaining.
.
See Engine Manual and Maintenance Label. Ser-
vice more often if used in severe conditions.
*
To be done by Factory Authorized Service Agent.
8 h
20 h
Wipe up spills.
Check fluid
levels. See
Section 5-4
or 5-5
Check and clean
spark arrestor screen.
See engine manual.
50 h
Clean and
tighten weld
terminals.
Service air cleaner
element. See engine
manual.
100 h
Change oil. See
engine manual and
maintenance label.
Check
spark
plugs.
Clean and tighten battery
connections (Electric
-Start models only).
Clean Fuel
sediment cup.
200 h
Replace
unreadable
labels.
Clean fuel
tank and
strainer.
300 h
Check valve
clearance.*
500 h
Repair or
replace cracked
cables.
Service welding generator
brushes and slip rings. Service
more often in dirty conditions.*
1000 h
Blow out or
vacuum inside.
During heavy
service, clean
monthly.