Section 3
Ice Machine Operation
3-5
ICE THICKNESS CHECK
The ice thickness probe is factory-set to maintain
the ice bridge thickness at 1/8” (3.2 mm).
1. Inspect the bridge connecting the cubes. It
should be about 1/8” (3.2 mm) thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase
bridge thickness, or counterclockwise to
decrease bridge thickness.
NOTE: Turning the adjustment 1/3 of a turn will
change the ice thickness about 1/16” (1.5 mm).
Ice Thickness Check
Make sure the ice thickness probe wire and the
bracket do not restrict movement of the probe.
SV1208
1/8” (3.2MM)
ICE BRIDGE
THICKNESS
ADJUSTING
SCREW
See also other documents in the category Manitowoc Ice Freezers:
- RF0300 (1 page)
- K00343 (1 page)
- AUCS-SI K00363 (1 page)
- FLAKE/CHIPLET QF2300 (150 pages)
- SD0672C (3 pages)
- K00055 (1 page)
- Q-0210 (1 page)
- K00372 (4 pages)
- QC0700 (1 page)
- RF1200 (2 pages)
- 7600143 (1 page)
- K00022 (1 page)
- F-STYLE OR NON MANITOWOC BIN 7601193 (3 pages)
- 7622333 (1 page)
- S (60 pages)
- K00114 (1 page)
- S0850M (38 pages)
- K00117 (1 page)
- K00368 (1 page)
- K00127 (1 page)
- 7626813 (1 page)
- S1400M (38 pages)
- S600M (40 pages)
- QM30 Series (28 pages)
- K00119 (1 page)
- K00142 (2 pages)
- E-0600 (2 pages)
- BR-0490N (2 pages)
- TIMER GSI 200 (2 pages)
- K00135 (1 page)
- 7626213 (4 pages)
- K00047 (1 page)
- Q (52 pages)
- MFD-50 (1 page)
- JR/QR0490N (1 page)
- BULKHEAD Q-1400 (2 pages)
- KEY CARD KIT K00152 (1 page)
- Q-1300 (3 pages)
- 7622073 (1 page)
- MAC 6 K059 (2 pages)
- K00349 (3 pages)
- SN20 (1 page)
- LEFT SIDE SPLASH SHIELD J-0320 (1 page)
- Q300 (45 pages)
- K00066 (1 page)