Operator Accessible Parameters

13

Setting the Operator Accessible Parameters

1.

ENTER THE OPERATOR PARAMETER MODE.

Press 'Steam' and 'Start / Stop' buttons together.

‘Temperature’ Display will show ‘PAS’.


The ‘Time’ Display will flash.

2.

SET PASSWORD

.

Rotate ‘Timer Control’ to set password;

(123) (Operator Password).


Press ‘Light On / Off’ button to confirm password.

‘Temperature’ Display
will show one of Parameter Codes.

‘Time’ Display will show value of the parameter.

3.

SETTING THE PARAMETERS.

Rotate ‘Timer Control’ to parameter required.


Press ‘Light’ button to confirm parameter. ‘Time’ display will flash.

While ‘Time’ display is flashing, rotate ‘Timer Control’ to

select value required.


Press ‘Light’ button to confirm value. ‘Time’ display will stop flashing.

4.

EXITING THE PARAMETER MODE.

Press ‘On-Off’ button, to return to ‘Stand-By’ mode.


Table of Operator Accessible Parameters

Parameter

Number

Description

Default

Setting

Turn -On Pre-Heating temperature - (60 - 260˚C).

150

Light Auto ‘Off’ Setting Time -

0 = ‘On/Off’.

1 = 1 minute auto ‘Off’.

2 = 2 minutes auto ‘Off’, etc.

1

Steam Injection setting time -

0 = Steam will be emitted for as long as ‘Steam’ button is pressed.

1 = Steam will be emitted for 1 second.

2 = Steam will be emitted for 2 seconds, etc.

1

Buzzer Volume - Can be adjusted from ‘0’ to ‘10’.

5

Program Pre-Heating Condition - (Can be adjusted from 0 to 30 degrees above pre-heat temperature).

10