M2d specifications – Meyer Sound M2D User Manual
Page 4
M2D specifications
1. The low-frequency power response
of the system will increase according
to the length of the array.
2. Recommended maximum operating
frequency range. Response depends
on loading conditions and room
acoustics.
3. Free field, measured with 1/3 octave
frequency resolution at 4 meters.
4. Measured with music at 1 meter.
5. At this frequency, the mid- and
high-frequency transducers produce
equal sound pressure levels.
6. Power handling is measured under
AES standard conditions: transducer
driven continuously for two hours
with band-limited noise signal
having a 6 dB peak-average ratio.
7. To eliminate interference at short
wavelengths, the two 10-inch cone
drivers work in combination at low
frequencies (60 Hz – 350 Hz). At
mid frequencies (350 Hz – 575 Hz)
only one cone driver is fed from
the crossover to maintain optimal
polar and frequency response
characteristics.
8. The driver is coupled to a
constant-directivity horn through
a proprietary acoustical manifold
(REM).
9. Amplifier wattage rating based on
the maximum unclipped burst sine-
wave rms voltage that the amplifier
will produce into the nominal load
impedance. Low channel 30 V rms
(42 V pk) into 2 ohms; high channel
32 V rms (45 V pk) into 8 ohms.
10. No automatic turn-off voltages.
Voltages above 265 V AC are fuse
protected but may cause permanent
damage to the power supply.
Voltages below 90 V AC may result in
intermittent operation.
meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702
T: +1 510 486.1166
F: +1 510 486.8356
[email protected]
www.meyersound.com
M2D - 04.112.011.01 B
Copyright © 2004
Meyer Sound Laboratories Inc.
All rights reserved
Operating Frequency Range
2
Frequency Response
3
Phase Response
Maximum Peak SPL
4
Dynamic Range
Horizontal Coverage
Vertical Coverage
Low/Mid Frequency
7
High Frequency
8
Type
Maximum Common Mode Range
Connectors
Input Impedance
Wiring
DC Blocking
CMRR
RF Filter
TIM Filter
Nominal Input Sensitivity
Input Level
Type
Output Power
THD, IM, TIM
Load Capacity
Cooling
Connector
Voltage Selection
Safety Agency Rated Operating Range
Turn-on and Turn-off Points
10
Current Draw:
Idle Current
Max Long-Term Continuous Current (>10 sec)
Burst Current (<1 sec)
Ultimate Short-Term Peak Current Draw
Inrush Current
60 Hz - 16 kHz
70 Hz - 14 kHz ±4 dB
650 Hz - 12 kHz ±45°
136 dB
>110 dB
90°
Varies, depending on array length and configuration
575 Hz
5
Two 10" cone drivers with neodymium magnets
Nominal impedance: 4
Ω
Voice coil size: 2"
Power-handling capability: 400 W (AES)
6
One 4" compression driver
Nominal impedance: 8
Ω
Voice coil size: 4"
Diaphragm size: 4"
Exit size: 1.5"
Power-handling capability: 250 W (AES)
6
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
Female XLR input with male XLR loop outputor VEAM all-in-one
connector (integrates AC, audio and network)
10 k
Ω
differential between pins 2 and 3
Pin 1: Chassis/earth through 220 k
Ω
, 1000 pF, 15 V clamp network
to provide virtual ground lift at audiofrequencies
Pin 2: Signal +
Pin 3: Signal -
Case: Earth ground and chassis
Differential DC blocking up to max common mode voltage
>50 dB, typically 80 dB (50 Hz - 500 Hz)
Common mode: 425 kHz
Differential mode: 142 kHz
Integral to signal processing (<80 kHz)
0 dBV (1 V rms, 1.4 V pk) continuous average is typically the onset
of limiting for pink noise and music
Audio source must be capable of producing a minimum of +20 dBV
(10 V rms, 14 V pk) into 600
Ω
inorder to produce maximum peak
SPL over the operating bandwidth of the loudspeaker
Two-channel complementary MOSFET output stages (class AB/
bridged)
700 W
9
<.02 %
2
Ω
low channel, 8
Ω
high channel
Convection; 24 V DC output for optional external fan
PowerCon or VEAM
Automatic
100 V AC - 240 V AC; 50/60 Hz
Continuous 90 V AC - 265 V AC; 50/60 Hz
0.35 A rms (115 V AC); 0.35 A rms (230 V AC); 0.35 A rms (100 V AC)
3.1 A rms (115 V AC); 1.6 A rms (230 V AC); 3.6 A rms (100 V AC)
3.2 A rms (115 V AC); 1.6 A rms (230 V AC); 3.7 A rms (100 V AC)
5.8 A pk (115 V AC); 2.9 A pk (230 V AC); 6.7 A pk (100 V AC)
9 A pk (115 V AC and 230 V AC); 8 A pk (100 V AC)
Equipped for two conductor twisted-pair network, reporting all
operating parameters ofamplifiers to system operator’s host
computer.
Notes:
Acoustical
1
Coverage
Crossover
Transducers
Audio Input
Amplifier
AC Power
RMS Network