Numeric value
A 2-byte signed hexadecimal value is represented by a set of 4-digit (4-byte) characters. The range
that can be specified is from 8000h to 7FFFh

ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character

Hex

Meaning

0

30

OFF

1

31

ON

Special parameters
Operation mode parameters
Character

Hex

Meaning

0000

30h 30h 30h 30h

Standby mode

0001

30h 30h 30h 31h

Operate mode

0002

30h 30h 30h 32h

Cool down mode

0004

30h 30h 30h 34h

Emergency mode (Not covered in this document)

3 External control command table

Function

Command

e

p

y

T

a

t

a

D

Request

Operate mode

ELSE

Numeric Value

ON/OFF

Special Data

Operate

U0F

O

Hide

U00

O

O

Left/Right Reversal

U17

O

O

Top/Bottom

Inversion

U18

O

O

Operation Mode

Z03

O

O

O

Operation mode: Only Request command is possible