Weld motr com pls wait, Over crnt low wfs, Estop – Miller Electric Remote Operator Interface User Manual
Page 30: Rmd done over aver, Rel trig err unkn, Wait, 2 . diagnostics (continued)
OM-217 834 Page 26
7-2.
Diagnostics (Continued)
WELD WAIT
•
The weld wait error indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
MOTR COM
•
The motor communication error indi-
cates motor board lost data communica-
tions. Press Jog/Purge button to clear error.
PLS WAIT
•
The uim communication error indicates
user interface board lost data
communications. Press Jog/Purge button
to clear error.
OVER CRNT
•
The over current error indicates welding
power source primary current is too high.
Check and correct input power. Press Jog/
Purge button to clear error.
LOW WFS
•
The low wire feed speed error indicates
actual wire feed speed is lower than wire
feed speed command. Check for
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
E STOP
•
The emergency stop error occurs if the
user presses an emergency stop button.
Reset the emergency stop button and press
Jog/Purge button to clear error.
RMD DONE
•
The RMD done error indicates the RMD
demo is completed. Press Jog/Purge button
to clear error.
OVER AVER
•
The over average error indicates that cur-
rent is outside the average range for the set
program parameters. Check and correct
program parameters. Press Jog/Purge but-
ton to clear error.
REL TRIG
•
The release trigger error indicates the
user held the trigger when starting a weld
program Press Jog/Purge button to clear
error.
ERR UNKN
•
The unknown error indicates a malfunc-
tion in the system somewhere. Press Jog/
Purge button to clear error.
WELD
MOTR
COM
PLS
WAIT
Indicates a weld
cycle wait error.
Indicates a motor
communication error.
Indicates a UIM
communication error.
OVER
CRNT
LOW
WFS
Indicates an
overcurrent error.
Indicates a low WFS
command error.
E
STOP
Indicates an
emergency stop error.
RMD
DONE
OVER
AVER
Indicates an arc
error.
Indicates an over
average current error.
REL
TRIG
ERR
UNKN
Indicates a trigger
closed error.
Indicates an
unknown error.
WAIT