beautypg.com

2. installing insulator kit – Miller Electric Remote Operator Interface User Manual

Page 14

background image

OM-217 834 Page 10

4-2. Installing Insulator Kit

804 165-A

Y Turn Off and disconnect

input power.

1

ROI Control

2

Insulator Plate

3

Mounting Plate

4

1/4-20x3/4 in Screw (4)

5

Nylon Shoulder Washer (4)

6

3/8 in Flat Washer (4)

Place insulator plate between ROI

base and metal mounting surface.
Place nylon shoulder washer over

screw.
Place flat washer over shoulder

washer.
Insert hardware assembly through

hole in metal mounting base, insu-

lator, and into ROI base (4 loca-

tions). Tighten hardware to secure

control.

1

2

3

4

5

6

1/2 in

Tools Needed: