beautypg.com

Type of gas – Maytag MDG30MNV User Manual

Page 20

background image

16

Maytag Co.

113307 - 7

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C. 14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

TYPE OF GAS

Liquid

Propane

Conversion Kit

Part Number

Btu

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty.

D.M.S.*

Part

Number

Qty. D.M.S.*

Part

Number

100,000 25,200

2

#29

140820

2

#46

140806

883321

2. Technical Gas Data

a. Gas Specifications

Shaded areas are stated in metric equivalents

*Measured at outlet side of gas valve pressure tap when gas valve is on.

b. Gas Connections

Inlet connection ............... 1/2” N.P.T.
Inlet supply size ............... 1/2” Diameter Pipe (minimum)
Heat input (per dryer) ..... 100,000 Btu/hr (25,200 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas ............................. #29 = 0.1360” (3.4540 mm).
Liquid Propane Gas ................. #46 = 0.810” (2.0574 mm).