beautypg.com

Indicators, Normal condition abnormal condition – MITSUBISHI ELECTRIC XD420U User Manual

Page 26

background image

EN-26

Indicators

This projector has two indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.

Normal condition

Abnormal condition

POWER

STATUS

CONDITION

NOTE

Stand-by

Lamp stand-by (about 1 minute)

The POWER button cannot be used to switch
between on and off.

The power is on. (Normal condition)

STATUS indicator

POWER indicator

Steady red

Off

Steady green

Blinking green

Steady green

Steady green

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

Abnormal temperature

The ventilation grilles is clogged with dust or dirt.

The room temperature is high.

Clean the ventilation grilles.

Relocate the projector to a cooler place.

The protection circuit is working or the lamp is in an abnormal con-
dition.

Wait until the STATUS indicator goes out, then
press the POWER button.

If the above solution is not effective, replace the
lamp.

The lamp operation time exceeds the time elapsed until the lamp
shutdown notice while the power is on. (See page 22.)

Replace the lamp.
Change with a new lamp if this problem recurs.

The lamp operation time exceeds the time elapsed until the lamp
shutdown notice while the power is off. (See page 22.)

The lamp operation time exceeds the time elapsed until the lamp
shutdown. (See page 22.)

The lamp cover isn’t closed.

Close the cover correctly.

Abnormal.

Contact your dealer.

Steady green

or

Steady red

Blinking orange

Steady red

Blinking green

Steady green

Blinking green/red

Steady red

Blinking red

Steady red

Steady red

Blinking green/red

Off

Blinking green/red

Steady

or

Blinking

01_ENG.fm Page 26 Friday, May 26, 2006 4:19 PM

This manual is related to the following products: