Warning, Nameplate, 2f68 – Marley Engineered Products PORTABLE UNIT HEATERS 482A User Manual
Page 2
GENERAL
Prior to operating heater, make sure the electrical outlet is of the
configuration and capacity appropriate for the heater. See outlet
configuration on front page of manual. No adapter is available for
this blade configuration and none should be used. The outlet pro-
vided must be a 240 volts grounded type. When properly installed,
it provides a ground connection through the cord of the heater to
protect the operator from electric shock. In workshops, locate
heater away from sources of wood dust.
FLOOR APPLICATION
The heater is for floor mounting only. Place the heater on floor or
other flat surface and insert plug into the proper wall outlet.
HEATER OPERATION
Set thermostat to its full counterclockwise position. Plug the unit
into a properly grounded 240 V outlet. (#6-20 for model 402, #6-30
for model 482). Set the thermostat to the full clockwise position.
The fan should come on and the unit will start heating the room.
When the room reaches comfort level, turn the thermostat coun-
terclockwise until the heater turns off. The heater will cycle auto-
matically around this preset temperature. To increase temperature,
turn the thermostat knob clockwise. To lower temperature, turn the
thermostat counterclockwise.
CLEANING AND STORAGE
Turn thermostat off and remove plug from electrical outlet before
cleaning heater. Use a soft cloth for dusting. For cleaning, use only
a damp rag and non-abrasive dish detergent. Do not use abrasive
chemical cleaners, as these may harm the finish.
If heater is used in very dusty location, use a vacuum cleaner dust
brush to remove dust and other foreign material from the grilles.
Always unplug cord and wrap around heater handle when not in
use. Move heater to a safe location for storage.
SERVICE
This heater does not require any routine maintenance other than
occasional cleaning to prevent clogging of intake grille opening. To
clean air intake grille, use vacuum with brush attachment or high
pressure air. The motor is permanently lubricated. Do not operate
the heater with a damaged cord or plug, or if the heater malfunc-
tions or has been damaged in any manner. Return heater to autho-
rized service facility for examination, electrical, or mechanical
adjustment, or repair. Call the toll free number listed for assistance
in locating the Marley authorized service center in your area.
WARNING
!
BE CAREFUL NOT TO DIRECT THE AIRSTREAM AT
DRAPERIES, FURNITURE, OR OTHER OBJECTS THAT
COULD BE DAMAGED BY HEAT. DO NOT PLACE THE
HEATER WHERE A SMALL CHILD MAY FALL OVER THE
HEATER. DO NOT PLACE THE HEATER WHERE THE POWER
CORD MAY BE WALKED ON, TRIPPED OVER, OR OTHER-
WISE SUBJECTED TO HARD USAGE.
NAMEPLATE
5200-2442-001
PPD029
6/99
How to order repair parts:
In order to obtain any needed repair or replacement parts,
warranty service or technical information, please contact
the Marley Engineered Products Service Center toll-free
by calling 1-800-642-HEAT.
When ordering replacement parts, always give the infor-
mation listed as follows:
1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture
WARNING
!
OPERATION OF THE SAFETY THERMAL LIMIT CONTROL INDI-
CATES THE HEATER HAS BEEN SUBJECTED TO SOME ABNOR-
MAL CONDITIONS. IT IS RECOMMENDED THAT THE HEATER
BE CHECKED BY A REPUTABLE ELECTRICIAN OR REPAIR SER-
VICE TO INSURE THE HEATER HAS NOT BEEN DAMAGED.
2
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are
warranted against defects in workmanship and materials for one
year from date of installation, except heating elements which are
warranted against defects in workmanship and materials for five
years from date of installation. This warranty does not apply to
damage from accident, misuse, or alteration; nor where the con-
nected voltage is more than 5% above the nameplate voltage;
nor to equipment improperly installed or wired or maintained in
violation of the product’s installation instructions. All claims for
warranty work must be accompanied by proof of the date of
installation.
The customer shall be responsible for all costs incurred in the
removal or reinstallation of products, including labor costs, and
shipping costs incurred to return products to Marley Engineered
Products Service Center. Within the limitations of this warranty,
inoperative units should be returned to the nearest Marley autho-
rized service center or the Marley Engineered Products Service
Center, and we will repair or replace, at our option, at no charge
to you with return freight paid by Marley. It is agreed that such
repair or replacement is the exclusive remedy available from
Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID
EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND
EXCLUDED FROM THIS AGREEMENT. MARLEY
ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR
CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO
THE PRODUCT, WHETHER BASED UPON NEGLIGENCE,
TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above exclusion or limitation
may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights which vary from state
to state.
For the address of your nearest authorized service center, con-
tact Marley Engineered Products in Bennettsville, SC, at 1-800-
642-4328. Merchandise returned to the factory must be
accompanied by a return authorization and service identification
tag, both available from Marley Engineered Products. When
requesting return authorization, include all catalog numbers
shown on the products.
MODEL
WATTS
DATE
VOLTS
PH
Hz
482A
WK-YY
240/208
1
60
4800/3600
2F68
MADE IN TAIWAN
SPX Corporation
470 Beauty Spot Rd. East