General Inspection
At least daily or prior to each use, the welder/AC generator
should be cleaned and inspected for deficiencies. Check for
loose, missing or damaged nuts, bolts or other fasteners.
Also check for fuel or oil leaks.
Engine Side:
For a more detail engine maintenance schedule refer to the
KUBOTA Engine Shop and Operator's Manuals.
Air Cleaner
Every 50 hours: The air cleaner employed on the KUBOTA
engine Model Z482-E is a dry type. NEVER apply oil to the
air cleaner. If welder/AC generator is used in severe dusty
areas service air cleaner element more frequently.
1. Release the air cleaner retaining clamps (Figure 31) and
remove the air cleaner element.
2. Wipe the inside of the air cleaner with a clamp cloth and
remove all dust and debris that may have accumulated
inside air cleaner body.
3. Use compressed air to clean air filter element. Blow
compressed air from the inside while turning the element.
BLW-400SSW — MAINTENANCE
ALWAYS keep the pressure of the
compressed air below 99 psi.
Cleaning the Fuel Strainer
Clean the fuel strainer if it contains dust or water. Remove
dust or water in the strainer cap and wash it in gasoline.
Securely fasten the fuel strainer cap so that fuel will not
leak. Check the fuel strainer every 200 hours of operation or
once a month.
Figure 31. Air Cleaner
CAUTION: