Multiquip MQ Power Duelweld Welder/Ac Generator BLW-400SSW User Manual
Page 23
BLW-400SSW-WELDER/AC GENERATOR— PARTS & OPERATION MANUAL— REV. #1 (06/15/01) — PAGE 23
BLW-400SSW — CONTROLS AND INDICATORS
Figure 6 shows the location of the controls and indicators. The
functions of each control or indicator is described below.
1.
DC Current Selector/Single-Use to select current when
using welder for single operator.
2.
Current Range Selector- Use to select for single or dual
welding operators.
3.
DC Current Selector/Dual- Use to select current when
using welder for dual operators.
4.
AC Voltmeter-Indicates the output of total voltage with
welder and/or generator.
5.
AC Circuit Breaker- This 53 amp main circuit breaker will
shut down current if welder/generator is overloaded.
6.
Engine Indicator Lamps- Lights red when the following
conditions occur:
7.
Preheat Indicator-Indicates the engine is warmed up for
welding/adding load.
8.
Ignition Switch – With key inserted turn clockwise to start
engine.
9.
Hour Meter – Indicates number of hours machine has
been in use or hours engine was run.
10. Idle Switch- Turn on for rpms to automatically adjust rpms
when a load is added.
11. Fuel Gauge – Indicates the amount of fuel in the fuel tank.
!
Low Oil Pressure
!
High Water Temperature
!
Electrical System Is Not Charging Properly
Table of Contents