beautypg.com

Multiquip MQ Power Duelweld Welder/Ac Generator BLW-400SSW User Manual

Page 23

background image

BLW-400SSW-WELDER/AC GENERATOR— PARTS & OPERATION MANUAL— REV. #1 (06/15/01) — PAGE 23

BLW-400SSW — CONTROLS AND INDICATORS

Figure 6 shows the location of the controls and indicators. The
functions of each control or indicator is described below.

1.

DC Current Selector/Single-Use to select current when
using welder for single operator.

2.

Current Range Selector- Use to select for single or dual
welding operators.

3.

DC Current Selector/Dual- Use to select current when
using welder for dual operators.

4.

AC Voltmeter-Indicates the output of total voltage with
welder and/or generator.

5.

AC Circuit Breaker- This 53 amp main circuit breaker will
shut down current if welder/generator is overloaded.

6.

Engine Indicator Lamps- Lights red when the following
conditions occur:

7.

Preheat Indicator-Indicates the engine is warmed up for
welding/adding load.

8.

Ignition Switch – With key inserted turn clockwise to start
engine.

9.

Hour Meter – Indicates number of hours machine has
been in use or hours engine was run.

10. Idle Switch- Turn on for rpms to automatically adjust rpms

when a load is added.

11. Fuel Gauge – Indicates the amount of fuel in the fuel tank.

!

Low Oil Pressure

!

High Water Temperature

!

Electrical System Is Not Charging Properly

Table of Contents

This manual is related to the following products: