beautypg.com

Location requirements – Maytag W10445417B User Manual

Page 10

background image

10

DRYER DIMENSIONS

23

3

/

8

"

(594 mm)

33

1

/

4

"

(845 mm)

23

1

/

4

"

(603 mm)

39"

(991 mm)

Back view:

3

1

/

4

"

(83 mm)

11

3

/

4

"

(299 mm)

27"

(686 mm)

NOTE: Most installations

require a minimum of

5" (127 mm) clearance

behind dryer for exhaust

vent with elbow. See

“Venting Requirements.”

LOCATION REQUIREMENTS

Check code requirements. Some codes limit, or do not permit,

installing dryer in garages, closets, mobile homes, or sleeping

quarters. Contact your local building inspector.

You will need:
n

A location allowing for proper exhaust installation.

See “Venting Requirements.”

n

A separate 30 amp circuit.

n

If using power supply cord, a grounded electrical outlet

located within 2 ft. (610 mm) of either side of dryer.

See “Electrical Requirements.”

n

Floor must support dryer weight of 115 lbs. (52 kg).

Also consider weight of companion appliance.

n

Level floor with maximum slope of 1" (25 mm) under entire

dryer. If slope is greater than 1" (25 mm), install Extended

Dryer Feet Kit, Part Number 279810. If not level, clothes

may not tumble properly and automatic sensor cycles may

not operate correctly.

n

For garage installation, place dryer at least 18" (460 mm)

above floor. If using a pedestal, you will need 18" (460 mm)

to bottom of dryer.

n

The dryer must not be installed or stored in an area where

it will be exposed to water and/or weather.

IMPORTANT: Do not operate, install, or store dryer where

it will be exposed to water, weather, or at temperatures below

45° F (7° C). Lower temperatures may cause dryer not to

shut off at end of sensor cycles, resulting in longer drying times.

Installation Clearances

For each arrangement, consider allowing more space for ease

of installation and servicing, spacing for companion appliances,

and clearances for walls, doors, and floor moldings. Space

must be large enough to allow door to fully open. Add spacing

on all sides of dryer to reduce noise transfer. If a closet door

or louvered door is installed, top and bottom air openings

in door are required.
Check code requirements. Some codes limit, or do not permit,

installation of the dryer in garages, closets, mobile homes, or

sleeping quarters. Contact your local building inspector.

Side view:

Front view:

Power supply

cord/cable

Vent

This manual is related to the following products: