POWER CONNECTION CHART
230/208 Volt
Power Supply Kits
with Current Leakage
Wall Plug
Heater Wattage
Detection Device
Configuration
Circuit Protective Device
@ 230/208 Volts
RAK3153
Tandem
15-Amp Time-Delay Fuse or Breaker
2.55/2.09 KW
RAK3203
Perpendicular
20-Amp Time-Delay Fuse or Breaker
3.45/2.82 KW
RAK3303*
Large Tandem
30-Amp Time-Delay Fuse or Breaker
5.00/4.10 KW
230/208 Volt
Heater Wattage
Power Supply Kits
Circuit Protective Device
@ 230/208 Volts
RAK4157
15-Amp Time-Delay Fuse or Breaker
2.55 KW/2.09 KW
RAK4207
20-Amp Time-Delay Fuse or Breaker
3.45 KW/2.82 KW
RAK4307*
30-Amp Time-Delay Fuse or Breaker
5.00 KW/4.10 KW
265 Volt
Heater Wattage
Power Supply Kits
Circuit Protective Device
@ 265 Volts
RAK5157
15-Amp Time-Delay Fuse or Breaker
2.55 KW
RAK5207
20-Amp Time-Delay Fuse or Breaker
3.45 KW
RAK5307*
30-Amp Time-Delay Fuse or Breaker
5.00 KW
*Not approved for use on 7000 BTUH units.
Power Cord Connections
Direct Connections