Electrical connection, Electrical connection –16, Power cord connection direct connection – GE Zoneline 4100 User Manual
Page 13
Installation Instructions
HOW TO CONNECT
ELECTRICAL SUBBASE
CONNECTION
1. Remove the room cabinet.
2. Connect to electrical power.
3. Review the following steps for applicable supply
voltages.
4. Reinstall the room cabinet.
Tandem
15 Amp.
230/208-volt receptacle configuration.
Perpendicular
20 Amp.
Large Tandem
30 Amp.
Power cords may include an arc fault interruption
or a leakage current detection interruption device.
A test and reset button is provided on the plug case
or the inline case. The device should be tested on
a periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the Zoneline and contact a
qualified service technician.
230/208-volt models may be installed using one
of the following electrical subbases:
*Not approved for use on 7000 BTU models.
Electrical subbases provide an enclosure for direct
connection or enclosed receptacles. The subbase kit
includes the power cord.
The instructions provided with the selected subbase kit
must be carefully followed. It is the responsibility of the
installer to ensure the connection of components is done
in accordance with these instructions and all electrical
codes.
Branch Circuit and
Proper GE
Unit Amperage Rating
Subbase Kit
15
RAK204D15P
20
RAK204D20P
30
RAK204D30P*
A power supply kit with LCDI must be used to supply power
to the Zoneline unit. The appropriate kit is determined by
the voltage, the means of electrical connection and
the amperage of the branch circuit.
Connections of 208 or 230-volt circuits may be with a
power supply kit or a junction box kit.
All wiring, including installation of the receptacle, must
be in accordance with the NEC and local codes,
ordinances and regulations. Codes require the use of
an arc fault or leakage current detection device on the
power cord except direct connect. Be sure to select the
correct cord for your installation.
Power supply kit
Appearance may vary.
Branch Circuit and
Proper GE Power Cord
Unit Amperage Rating
with LCDI Device
15
RAK3153
20
RAK3203
30
RAK3303*
230/208 VOLT ELECTRICAL CONNECTION OPTIONS
*Not approved for use on 7000 BTU models.
POWER CORD
CONNECTION
DIRECT CONNECTION
Order the following Kit for 230/208-volt direct
connection as required:
*Not approved for use on 7000 BTU models.
Skip to the “MAKE ELECTRICAL CONNECTION TO THE UNIT”
section.
Branch Circuit and
Power Supply
Power
Unit Amperage Rating
Accessory
Supply Kit
15
RAK4002A
RAK4157
20
RAK4002A
RAK4207
30
RAK4002A
RAK4307*
13