beautypg.com

0specifications, 1technical specifications – GarrettCom P62-Series User Manual

Page 6

background image

Magnum P62-Series Hardened Switches Installation and User Guide (08/03)

2

www GarrettCom com

.

.

Rev A 04/01: This revision is the initial release of the P62F Hardened Switches user manual.

1.0

SPECIFICATIONS

1.1

Technical Specifications
Ports Performance

Fiber, and when an auto-negotiating port is operating at 100Mbps:

Data Rate: 100Mbps

When an RJ-45 auto-negotiating port is operating at 10 Mbps:

Data Rate: 10 Mbps

For mP62 models, RJ-45 ports are S/W controlled for speed and F/H

duplex, crossover (MDI – MDIX) is automatically handled

Network Standards

100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX
10 Mb: Ethernet IEEE 802.3, 10BASE-T
Auto-sensing for speed: IEEE 802.3u; 802.3x flow control
For managed mP62 models, IEEE 802.1p QoS and 802.1d Spanning Tree
For mP62 management software, see Section 2.2.3

Packet-Processing Between Domains is non-blocking

Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
Processing type: Store and Forward
Auto-learning: 4K address table (16K on P62F), shared for all ports
Packet buffers: 256KB, dynamically shared on all domains
Latency (not including packet time): 100 to 10 Mbps: 5

µ

s

10 to 100Mbps: 5

µ

s

Path Delay Value: 50 BT on all ports

Maximum Ethernet Segment (or Domain) Lengths

10BASE-T (Unshielded twisted pair)

- 100 m (328 ft)

100BASE-TX (CAT 5 UTP)

- 100 m (328 ft)

100BASE-FX, full-duplex: (multi-mode)

- 2.0 km (6,562 ft)

100BASE-FX, full-duplex: (single-mode)

- 20.0 km (65,620 ft)

100BASE-FX, full-duplex: (single-mode, long) - 40.0 km (131,240 ft)

Operating Environment

Ambient Temperature: -40

°F to 170°F for mP62 (160°F for P62F)

(-40

°C to 75°C for mP62, 70°C for P62F))

Cold start down to -20

°C

Storage Temperature: -40

° to 185°F (-40°C to 85°C)

Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 50,00 ft. (-60 to 15,000m)
“Plenum rated” for above-the-ceiling installation in office areas
IEC 529 rated IP51 (holds out dust, vertical water)
Operating Shock and Vibration: Meets Bellcore GR-63-CORE