Magnum P62-Series Hardened Switches Installation and User Guide (08/03)

23

www GarrettCom com

.

.

longer distances, about 20Km with the single-mode SC.

The same procedures as for multi-mode fiber apply to single-mode fiber connectors.

Follow the steps listed in Section 3.2.2 above.

3.2.5

Power Budget Calculations for P62-Series Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute

the power budget. To calculate the power budget of different fiber media installations using
Magnum products, the following equations should be used:
OPB (Optical Power Budget) = P

T

(min) - P

R

(min)

where P

T

= Transmitter Output Power, and P

R

= Receiver Sensitivity

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125

µm

(m.m.) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

The following data has been collected from component manufacturer’s (HP’s and Siemens’) web
sites and catalogs to provide guidance to network designers and installers.

Fiber

Port

Module

Speed,

Std.

Mode

Std. km

fdx

(hdx)

Wave-

length

nm

Cable

Size

µm

X’mitr

Output

P

T ,

dB

R’cvr

Sens.

P

R ,

dB

Worst

OPB,

dB

Worst*

distance
Km, fdx

typical

OPB,

dB

typical*

distance

Km, fdx

P62-

xMSC

100Mb

FX

Multi-

mode

2

(0.4)

1300 62.5/125

50/125

-20

-23.5

-31
-31

9.0
5.5

2.5
2.0

14
12

5
4

P62-

xSSC

100Mb

FX

Single-

mode

20

(0.4)

1300

9/125

-15

-31

14

28

17.5

35

“Long

Reach”

100Mb

FX

Single-

mode

40

(0.4)

1300

9/125

-5

-34

27

54

32.5

65

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long

distances (i.e., over approx. 400 meters) can be achieved

only

if the following factors are

both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, and

The worst-case OPB of the fiber link must be greater than the fiber cable’s passive
Attenuation.