Servicing – Goodmans ASX User Manual
Page 48
SERVICING
48
S-16F CHECKING GE X13
TM
MOTORS
The GE X13
TM
Motor is a one piece, fully encapsulated, 3
phase brushless DC (single phase AC input) motor with ball
bearing construction. Unlike the ECM 2.3/2.5 motors, the
GE X13
TM
features an integral control module.
Note: The GE TECMate will not currently operate the GE
X13
TM
motor.
1. Using a voltmeter, check for 230 volts to the motor
connections L and N. If 230 volts is present, proceed to
step 2. If 230 volts is not present, check the line voltage
circuit to the motor.
2. Using a voltmeter, check for 24 volts from terminal C to
either terminal 1, 2, 3, 4, or 5, depending on which tap is
being used, at the motor. If voltage present, proceed to
step 3. If no voltage, check 24 volt circuit to motor.
3. If voltage was present in steps 1 and 2, the motor has
failed and will need to be replaced.
Note: When replacing motor, ensure the belly band is
between the vents on the motor and the wiring has the
proper drip loop to prevent condensate from entering the
motor.
C L G N
1 2 3 4 5
High Voltage
Connections
3/16"
Low Voltage Connections
1/4”
GE X13
TM
MOTOR CONNECTIONS
S-16E BLOWER PERFORMANCE DATA
SPEED
STATIC
MBR800**-*
SCFM
MBR1200**-*
SCFM
MBR1600**-*
SCFM
MBR2000**-*
SCFM
0.1
1,240
1,500
1,800
2,160
0.2
1,170
1,460
1,740
2,080
0.3
1,120
1,360
1,680
1,990
0.4
1,060
1,280
1,610
1,890
0.5
980
1,200
1,520
1,790
0.6
900
1,110
1,430
1,690
0.1
900
1,380
1,540
1,730
0.2
850
1,320
1,490
1,670
0.3
790
1,270
1,450
1,590
0.4
740
1,200
1,400
1,520
0.5
680
1,140
13,560
1,420
0.6
605
1,040
1,280
1,320
0.1
650
1,170
1,130
1,520
0.2
590
1,130
1,100
1,450
0.3
540
1,080
1,070
1,360
0.4
500
1,020
1,030
1,290
0.5
430
950
990
1,200
0.6
330
830
930
1,090
HIGH
MEDIUM
LOW
NOTE: External static is for blower @ 230 Volts. It does not include Coil, Air Filter or Electric Heaters.