beautypg.com

Servicing, Warning – Goodmans ASX User Manual

Page 39

background image

SERVICING

39

WARNING

Line Voltage now present.

1

2

3

4

5

OHMMETER

TESTING FAN RELAY

4. Using an ohmmeter, test between 2 and 4 - should read

continuous . Test between 5 and 6 - should read open.

5. If not as above, replace the relay.

S-10 COPELAND COMFORT ALERT™

DIAGNOSTICS

Applies to ASX /ASZ and DSX/DSZ units

Comfort Alert™ is self-contained with no required external
sensors and is designed to install directly into the electrical
box of any residential condensing unit that has a Copeland
Scroll™ compressor inside.

Once attached, Comfort Alert™ provides around-the-clock
monitoring for common electrical problems, compressor
defects and broad system faults. If a glitch is detected, an
LED indicator flashes the proper alert codes to help you
quickly pinpoint the problem. See Diagnostic Table on
following page.)

This manual is related to the following products: