SECTiON 2: CiRCUiT REQUiREMENTS
full Load amperage Draw
g0671 @ 220V ..................................... 32 Amps
g0672 @ 220V ..................................... 34 Amps
g0673 @ 220V ..................................... 30 Amps
g0673 @ 440V ..................................... 15 Amps
NOTICE
The Model G0671/G0672/G0673 is prewired
for 220v operation. if you plan to use your
Model G0673 at 440v, you MUST have a
qualified electrican perform the 440v con-
version described on this page.
Operation
Serious personal injury could occur if you
connect the machine to power before com-
pleting the setup process. DO NOT connect
the machine to the power until instructed
later in this manual.
Electrocution or fire could
result if machine is not
grounded and installed in
compliance with electrical
codes. Compliance MUST
be verified by a qualified
electrician!
figure 6. hardwired locking disconnect switch.
8dcYj^i
id
BVX]^cZ
8dcYj^i
id
EdlZgHdjgXZ
hardwired locking
disconnect switch
power Connection Device
We recommend having an electrician hardwire
the machine (using a metal conduit setup) directly
to a locking disconnect switch (
figure 6), which is
directly connected to the power source.
g0671 Minimum Circuit size .................40 Amps
g0672 Minimum Circuit size .................50 Amps
g0673 Minimum Circuit size (220V) .....40 Amps
g0673 Minimum Circuit size (440V) .....20 Amps
the Model
g0673 can be converted for 440V
operation. this conversion job consists of discon-
necting the dust collector from the power source,
changing the magnetic switch, and rewiring the
motor for 440V operation, as shown on
page 42.
the necessary magnetic switch for this procedure
can be purchased by calling grizzly Customer
service at (800) 523-4777 and ordering Model
g8296 (3-phase 440V 10hp Mag switch).
All wiring changes must be inspected by a quali-
fied electrician before the dust collector is con-
nected to the power source. if, at any time during
this procedure you need help, call grizzly tech
support at (570) 546-9663.
440v Conversion
power Supply Circuit Requirements
you Must connect your machine to a grounded
circuit that is rated for the amperage given below.
never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance
with wiring codes.
if you are unsure about the
wiring codes in your area or you plan to con-
nect your machine to a shared circuit, consult
a qualified electrician.