Adjustments continued – Garland CG-60F User Manual
Page 8
Part # 4520498 (11/24/08)
Page 8
ADJUSTMENTS Continued
Drawing A
Place the probe
within a
1 1/2 " circle
for maximum
accuracy
5 7/8"
12"
12"
12"
10"
2 . Place the surface temperature probe in the locations
indicated on Diagram A . Watch the amber indicator for
the zone being measured . When the amber indicator
is ON the burner for that zone is on . When the amber
indicator goes OFF note the temperature . The measured
temperature at the time the amber indicator switches off
should be no more than ± 5°F from the set temperature .
If the error is greater than ±5°F, but less than ± 10° F, then
firmly grasp the thermostat dial (be sure to not change
the 360° F setting) and loosen the dial set screw so that
the dial can rotate freely on the thermostat shaft .
Carefully rotate the dial to indicate the temperature
registered by your temperature indicating device and re-
tighten the set screw . Each minor line on the thermostat
dial’s scale is 5°F .
Reposition the dial to the calibration temperature
setting of 360° F . Allow sufficient time for the grill
surface temperature to stabilize and repeat the above
instructions .
If the temperature is greater than ± 10°F, consult a service
technician .