GarrettCom MAGNUM 6KQE User Manual
Page 7
Magnum 6KQE Managed Edge Switch Installation and User Guide 02/09
2
www GarrettCom com
.
.
1000BASE-SX, full-duplex, multi-mode (50
μm cable) - 550m
1000BASE-LX, full-duplex, multi-mode (50, 62.5
μm cable) - 550m
1000BASE-LX, full-duplex, single-mode (9
μm cable) - 5km
1000BASE-ZX, full duplex, single-mode (9
μm cable) - >70km
Fiber Multi-mode connector types supported:
Fiber Port, MTRJ-type (plug-in): SFF Fiber multi-mode 100BASE-FX
Fiber Port, LC-type (plug-in): SFF Fiber multi-mode 100BASE-FX
Fiber Port, 1000BASE-SX, SFP modules
Fiber Single-mode connector types:
Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX
Fiber Port, 1000BASE-LX, SFP modules
LEDs: Per Port (one set at the port, one set on swivel top on right side)
(see section 5.1.1 and 5.1.2 for detailed LED configurations)
Operating
Environment
Ambient Temperature:
-40
° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating
-40
° to 195° F (-40° to 85°C) for IEC 60068 Type Test short term rating
Storage Temperature: -60
°to 210°F (-50°to 100°C)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating (humidity protection) optional: Request quote
Alarm Relay Contacts
One NC indicating internal power, one NC software controllable
Packaging
Enclosure: High strength extruded aluminum
Dimensions: 6.85 in. H x 7.5 in. W x 2.0 in. D
17.4 cm H x 19.1 cm W x 5.08 cm D
Cooling method: Convection, fully-enclosed ribbed-surface aluminum case
used as a sink, designed for vertical mounting, no fans
Weight: 3 lbs. (1.3 kg)
Management Console connector
Serial DB-9, see details at sec. 3.6
DC Power Supply (Internal, floating ground design)
12VDC Power Input nominal (range 8 to 18VDC)
24VDC Power Input nominal (range 18 to 36VDC)
-48VDC Power Input nominal (range 36 to 60VDC)
125VDC Power Input nominal (range 88 to 150VDC)
250VDC Power Input nominal (range 160 to 300VDC)
Std. Terminal Block : “ -, GND, + ”