beautypg.com

GarrettCom MAGNUM 6KQE User Manual

Page 7

background image

Magnum 6KQE Managed Edge Switch Installation and User Guide 02/09


2

www GarrettCom com

.

.

1000BASE-SX, full-duplex, multi-mode (50

μm cable) - 550m

1000BASE-LX, full-duplex, multi-mode (50, 62.5

μm cable) - 550m

1000BASE-LX, full-duplex, single-mode (9

μm cable) - 5km

1000BASE-ZX, full duplex, single-mode (9

μm cable) - >70km

Fiber Multi-mode connector types supported:

Fiber Port, MTRJ-type (plug-in): SFF Fiber multi-mode 100BASE-FX

Fiber Port, LC-type (plug-in): SFF Fiber multi-mode 100BASE-FX

Fiber Port, 1000BASE-SX, SFP modules

Fiber Single-mode connector types:

Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX

Fiber Port, 1000BASE-LX, SFP modules

LEDs: Per Port (one set at the port, one set on swivel top on right side)

(see section 5.1.1 and 5.1.2 for detailed LED configurations)

Operating

Environment

Ambient Temperature:

-40

° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating

-40

° to 195° F (-40° to 85°C) for IEC 60068 Type Test short term rating

Storage Temperature: -60

°to 210°F (-50°to 100°C)

Ambient Relative Humidity: 5% to 95% (non-condensing)

Altitude: -200 to 13,000 ft. (-60 to 4000m)

Conformal Coating (humidity protection) optional: Request quote

Alarm Relay Contacts

One NC indicating internal power, one NC software controllable


Packaging

Enclosure: High strength extruded aluminum
Dimensions: 6.85 in. H x 7.5 in. W x 2.0 in. D

17.4 cm H x 19.1 cm W x 5.08 cm D

Cooling method: Convection, fully-enclosed ribbed-surface aluminum case

used as a sink, designed for vertical mounting, no fans

Weight: 3 lbs. (1.3 kg)

Management Console connector

Serial DB-9, see details at sec. 3.6

DC Power Supply (Internal, floating ground design)

12VDC Power Input nominal (range 8 to 18VDC)

24VDC Power Input nominal (range 18 to 36VDC)

-48VDC Power Input nominal (range 36 to 60VDC)

125VDC Power Input nominal (range 88 to 150VDC)

250VDC Power Input nominal (range 160 to 300VDC)

Std. Terminal Block : “ -, GND, + ”