beautypg.com

1 generator identification – Generac Power Systems 004701-0 User Manual

Page 6

background image

4

1. Generator Air Intake
2. Engine Start/Stop Switch
3. Fuse
4.

Optional Remote Panel Receptacle (Side View)

5.

Generator AC Output Leads (Side View)

6. Fuel Primer Switch
7. Circuit

Breaker

8. Starter

Contactor

9. Fuel

Inlet

10. Fuel Pump (Behind Access Panel)
11. LP Regulator/Solenoid
12. Oil Filter
13. Oil Drain Cap
14. Oil Dipstick
15. Air Filter (Behind Access Panel)
16. Oil Fill
17. Spark Plug

Section 1 – General Information

Recreational Vehicle Generator

Please record the following information from the generator DATA LABEL or information decal.

1. Model

Number

_____________________

2. Serial

Number

__________________

3. kW

Rating

_________________________

4. Rated

Voltage

__________________

*

S E R V IC E A C C E S S

P A N E L

OIL LEVEL:

CHECK DAILY

AIR FILTER:

CLEAN PREFILTER
EVERY 100 HOURS.
REPLACE ELEMENT
EVERY 250 HOURS.

OIL & OIL FILTER:

CHANGE EVERY 100

(IF NECESSARY)

EVERY 500 HOURS.

HOURS. REPLACE PLUGS

PLUGS EVERY 100

INSPECT & CLEAN

SPARK PLUGS:

REPLACEMENT INFORMATION

*

PERFORM MORE OFTEN IN DUSTY CONDITIONS

AIR FILTER LOCATED BEHIND PANEL.

MAINTENANCE SCHEDULE

AIR FILTER P/N:

0D3262

070185

OIL FILTER P/N:

SPARK PLUG P/N:

072347

OIL CAPACITY WITH FILTER:

0.8L/0.84QT

TEMPERATURE

SAE VISCOSITY

32°F AND HIGHER

10°F TO 100°F

0°F TO 80°F

-20°F TO 50°F

5W-30

10W-30

15W-40

30

WHEN SERVICE OR PARTS ARE NEEDED IN

THE USA OR CANADA, CONTACT THE GENERAC

SERVICE LOCATOR AT 1-800-333-1322.

HOURS. (OR ANNUALLY)

PREFILTER P/N:

0D4511

FUEL FILTER P/N:

087769

FUEL FILTER:

CHANGE EVERY 400
HOURS. (OR ANNUALLY)

*

*

P R I M E

F U E L

S T O P

S T A R T

3 0 A

C .B .

1 5 A

F U S E

CONTROL CENTER

NEG.

BATTERY

FUEL

INLET

BATTERY

POS.

REMOTE

1

2

3

4

5

6

7

8

9

15

11

12

13

14/16

17

10

1.1 GENERATOR IDENTIFICATION