GE CS980SN User Manual
Cs980sn, Ge café free-standing radiant range
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Electrical Requirements: 240v/208v; 60Hz, 40A
Effective January 1, 1996, the National Electrical
Code requires that new construction (not
existing) utilize a 4-conductor connection to an
electric range.
Receptacle Locations: Locally approved flexible
service cord or conduit must be used because
terminals are not accessible after range
installation. See shaded area in drawing for
location of electrical outlet box. Recommended
outlet locations allow range to be installed
directly against wall.
Note: 30" ranges conform to U.L. requirements
for 0" spacing from adjacent walls below
countertops. To reduce possibility of scorching
walls, engineering recommends a minimum of
1-1/2" spacing to allow for possible extended,
high-heat, no-load heating element operation.
Installation information: Before installing,
consult installation instructions packed with
product for current dimensional data.
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Dimensions and Installation Information (in inches)
CS980SN
GE Café Free-Standing Radiant Range
30"
37-1/4"*
26-1/2"
46-3/4"
36-1/4"
+_
1/4
*41-1/4" with optional backguard kit
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
Receptacle locations: Locally approved flexible service cord or
conduit must be used because terminals are not accessible after
range installation. See shaded area in drawing for location of
electrical outlet box. Recommended outlet locations allow range
to be installed directly against wall.
Specification Created 8/08
221003
30"
37-1/4"*
26-1/2"
46-3/4"
36-1/4"
+_
1/4
*41-1/4" with optional backguard kit
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
Receptacle locations: Locally approved flexible service cord or
conduit must be used because terminals are not accessible after
range installation. See shaded area in drawing for location of
electrical outlet box. Recommended outlet locations allow range
to be installed directly against wall.