beautypg.com

2 product description - general, Product description - general – GarrettCom MAGNUM DS80F User Manual

Page 10

background image

Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (05/04)

10

2.2

Product Description - General

The DS80F Dual-Speed Personal Hubs with a Fiber Port, and the DS80C model with

all copper ports, offer the flexibility of 100Mbps switched fiber link upstream with the

convenience of dual-speed 10/100 copper ports for workplace LAN connections.

Magnum D80F “Fiber” models have been designed with one full-duplex 100Mbps

switched fiber port, one “N-way” switched RJ-45 and six half-duplex 10/100 auto-negotiating

RJ-45 ports. The DS80C “Copper” model has been designed with all eight RJ45 ports, two

switched ports with “N-way” capability and six half duplex 10/100 auto-negotiating ports. For

half- or full duplex selection on the two switched ports, see sections 4.3 and 4.4.

Ports #3 to 8 can independently identify (via IEEE 802.3u auto-sensing) and accept

either 100Mbps or 10Mbps Ethernet signals, adapting to match the highest speed of the

connected device. While the switched fiber port is typically for a backbone connection (note –

no media converter is required), the switched RJ-45 port can be used at 100Mb. FDX for

Figure 2.2.1: DS80F & DS80C is functionally both a 10Mbps and a 100Mbps hub in one

high-performance workplace servers or to cascade to another DS80-series for expansion. There

are separate internal traffic domains in Magnum DS80F & DS80C hubs, one for the 100Mbps

traffic and one for the 10Mbps traffic.

DS80F & DS80C ports #3 to 8 can connect into either the 100 or the 10Mbps traffic

domain, and can also change from one traffic domain to the other at any time without affecting

the speed of other ports. The automatic per-port speed-sensing is always ready (it takes place at

LINK enable, see Section 4.2 for details), allowing the connected devices to change speed at any

time without impairing the operation of the other ports and connected devices.

Tx Rx

UPLINK

F

H

= X

2SW

UPLINK

3 4 5 6 7 8

1SW

Magnum DS80 Dual Speed

Personal Hub

PORTS 1SW 2SW 3 4 5 6 7 8

Speed
Link/Act

F/H

Power

Error

GARRETT

12V, 1.5Amps

Magnum 500-series

DS80F or DS80C

GARR ETT

PWR

1 2 3 4

Magnum

8000E

Stacka ble

Hub

5 6 7 8

9 10 11 12

GARR ETT

PWR

1 2 3 4

5 6 7 8

9 1 0 11 12

10Mbps Hub

100Mbps Hub

www GarrettCom com

.

.

This manual is related to the following products: