Air conditioner

The air conditioner

Make sure the air conditioner plug is pushed completely

does not start

is unplugged

into the outlet.

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

breaker is tripped

the fuse or reset the breaker.

Power failure

The unit will automatically re-start in the settings last

used after the power is restored.

There is a protective time delay (approximately

3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling or heating for 3 minutes after it
is turned back on.

The current interrupter

Press the RESET button located on the power cord plug.

device is tripped

If the RESET button will not stay engaged, discontinue

use of the air conditioner and contact a qualified service
technician.

Air conditioner

Ice blocks the air flow

Set the mode control at Fan Only or Hi Cool with the

freezing up

and stops the air conditioner

temp control at a warmer setting.

from cooling the room

Air conditioner does not

Airflow is restricted

Make sure there are no curtains, blinds or furniture

cool as it should

blocking the front of the air conditioner.

The temp control may

Turn the temperature knob clockwise as far as possible.

not be set correctly

The air filter is dirty

Clean the filter at least every 30 days. See the Operating

Instructions section.

The room may have been hot

When the air conditioner is first turned on you need

to allow time for the room to cool down.

Cold air is escaping

Check for open furnace floor registers and

cold air returns.

Set the air conditioner’s vent to the closed position.

Cooling coils have iced up

See “Air conditioner freezing up” above.

Air conditioner does not

Airflow is restricted

Make sure there are no curtains, blinds or furniture

warm as it should

blocking the front of the air conditioner.

The temp control may

Turn the knob counterclockwise as far as possible.

not be set low enough

The lowest setting provides maximum warming.

The air filter is dirty

Clean the filter at least every 30 days. See the Operating

Instructions section.

The room may have been cold

When the air conditioner is first turned on, you need to

allow time for the room to warm up.

Warm air is escaping

Check for open furnace floor registers and

cold air returns.

Water drips outside

Excessively hot and

This is normal.

humid weather

Water drips indoors

The air conditioner is not

For proper water disposal, make sure the air conditioner

tilted to the outside

slants slightly from the case front to the rear.

Water collects in

Moisture is removed from

This is normal for a short period in areas with

base pan

indoor air and drains into

little humidity; normal for a longer period in very

rear of a cabinet where a fan

humid areas.

blows it against the outdoor