42
INSTALLATION INSTRUCTIONS
INSTALLING THE ANTI-TIP DEVICE
WARNING:
• Range MUST be secured with an
approved Anti-Tip device.
• Unless properly installed, the range could
be tipped by you or a child standing,
sitting or leaning on an open door.
• After installing the Anti-Tip device, verify
that it is in place by carefully attempting
to tilt the range forward.
• This range has been designed to meet all
recognized industry tip standards for all
normal conditions.
• The use of this device does not preclude
tipping of the range when not properly
installed.
• If the Anti-Tip device supplied with the
range does not fit this application, use the
universal Anti-Tip device WB02X7909.
9
LEVELING THE RANGE
1. Remove the storage
drawer or kick panel.
2. Use a 3/16
″
open-end or
socket wrench to back out
both rear leveling legs
approximately two turns.
3. Use a 1
3
⁄
8
″
open-end or
adjustable wrench to back
out the front leveling legs
two turns.
4. Install the oven shelves
in the oven and position
the range where it will
be installed.
5. Check for levelness by placing a spirit level
or a cup, partially filled with water, on one of the
oven shelves. If using a spirit level, take two
readings—with the level placed diagonally first
in one direction and then the other.
6. Adjust the leveling legs until the range is level.
7. After the range is level, slide the range away
from the wall so that the Anti-Tip device can be
installed.
8