beautypg.com

Factory settings, Adjustments, Page 2 b-series – Grindmaster Insulated Decanter Brewer AMW B-Series User Manual

Page 2

background image

FACTORY SETTINGS

(for each dispense head)

• Tank temperature is set at 200 degrees F.

• Brew time is pre-set at 2:20. (Volume/time to be set on-site)

• Pulse Brew is set for 1 pulse, 20 sec on, 20 sec off.

• Warmer Energy Savings mode is set for 60-minutes. (“OFF” for models without warmers)

• Low Temp / No Brew option is set to “OFF” or disabled.

• Pour over setting override is set to “no” or plumb in.

• Settings lock-out jumper on controller is set in “unlock” position.

ADJUSTMENTS:

Refer to B-Series Programming Chart on page 5.

NOTE:

Set each dispense head individually o

n two head models with two controllers and serial numbers A166225 and

lower (without a -P suffix). Tank temperature must be set to the same setting on both heads in order for the unit to

operate properly.

Tank Temperature:

Left display controls this.

• Press-and-hold both “up” and “down” arrows for 5 seconds.
• The display will indicate either “d F” or “d C”. (Fahrenheit or Celsius)
• Press up or down arrow to change from one scale to the other.
• Press “BREW” button to accept and proceed to the next setting.
• The display will read temperature value in the scale previously selected.
• Press up or down arrow to change temperature value.
• Press “BREW” button to accept and proceed to the next setting.

Brew Time:

• The display will read “br ”. (brew time)
• Press “BREW” button to proceed to the next setting.
• The display will read the set brew time in minutes and seconds. (ex: 2.20)
• Press up or down arrow to change time value.
• Press “BREW” button to accept and proceed to the next setting.

Pulse Brewing Mode:

• The display will read “P-b”. (pulse brew)
• Press “BREW” button to proceed to the next setting.
• The display will read “OFF” - “1”- ”6”.
• Press up or down arrow to change number of pulses.
• Press “BREW” button to proceed to the next setting.
• The display will read “0.05” - “0.30”.
• Press up or down arrow to change pulse-on time for each pulse in seconds.
• Press “BREW” button to proceed to next setting.
• The display will read “0.05” - “0.30”.
• Press up or down arrow to change pulse-off time for each pulse.
• Press “BREW” button to accept and proceed to the next setting.

Energy Savings Mode (Warmer shut-off):

• The display will read “E-S”. (energy savings)
• Press “BREW” button to proceed to the next setting.
• The display will read “Off” - “10” - “240” in multiples of 10.
• Press up or down arrow to change time value in minutes. Must be “OFF” for models without warmers.
• Press “BREW” button to accept and proceed to the next setting.

Low Temp/No Brew Mode:

• The display will read “Ltn” (Low Temp/No Brew).
• Press “BREW” button to proceed to the next setting.
• Press up or down arrow to change to “ON” or “OFF”.
• Press “BREW” to accept and proceed to the next setting.

Page 2

B-SERIES