Design guide, The installation space, Dimensions and clearances – GE Monogram ZICS360N LH User Manual

Page 3

background image

Design Guide

THE INSTALLATION SPACE

The finished cutout width must be 35-1/2".

Water And Electrical Locations
The opening must be prepared with the electrical and
water supply located as shown.

The cutout depth must be 24".

Designed for industry standard flush installation. The
refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.

Additional Specifications

• A 115 volt 60Hz., 15 or 20 amp power supply is

required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install a
properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.

Note:

GFI (ground fault interrupter) is not

recommended.
• Water line can enter the opening through the floor

or back wall. The water line should be 1/4" O.D.
copper tubing between the cold water line and
water connection location, long enough to extend
to the front of the refrigerator. Installation of an
easily accessible shut off valve in the water line is
recommended.

DIMENSIONS AND
CLEARANCES

* Shipping height. The

height may
be adjusted from
83-1/2" to 84-1/2" by
adjusting leveling legs
and wheels.

Product Clearances
These refrigerators are
equipped with a 2 position
door stop. The factory set
130

°

door swing can be

adjusted to 90

°

if clearance

to adjacent cabinets or
walls is restricted.

36"

Frame to Frame

Width

*84"

35"

Case Width

130

°

Door Swing

90

°

Door Swing

3

23-7/8"
Behind
Frame

36-3/4"

4" Minimum

to Wall

90

°

7"

Wall View

Electrical

Area

84-1/2" max
83-1/2" min

Finished

Opening

74-1/2" From

Floor to Bottom

of Electrical

10"

5"

3 1/2"

5"

3 1/2"

Water Supply

24" Cutout Depth

35-1/2"

Finished Width

2-5/16"

Allow 25" minimum clearance for a full 130

°

door

swing. Allow 15" for pan removal.

4" minimum clearance is required when door swing is
adjusted to 90

°

. If the 90

°

door stop position is used,

pan access is maintained, but pan removal is re-
stricted bottom pans.

See illustrations pages 4 and 5 to determine door
swing interaction with adjacent cabinets or
countertops.

25"

Minimum

to Wall

130

°

ZUG2, ZUGSS2 Unified Grille Panel Kit
• If you are installing two refrigerators, side by side,

the installation space must be 71-1/2" wide.

Note: Additional cutout width may be required when side panels
are used. Add side panel thickness to the finished cutout to
calculate rough-in width.

• The water and electrical locations for each product

must be located as shown.

• A separate 115V, 60Hz., 15 or 20 amp power supply

is recommended for each product.

2-5/16"

74-1/2" From

Floor to Bottom

of Electrical

84-1/2" max

83-1/2" min

Finished
Opening

71-1/2" Finished Width

Electrical

5"

3-1/2"

24" Cutout
Depth

Water Supply

Wall View

24-3/16"

26"

7"

10"

7"

10"

Water Supply

26"

5"

3-1/2"