6 specifications, 1 fuel requirements (gasoline), 1 fuel consumption (gph) – Guardian Technologies 004702-0 User Manual
Page 8: 2 engine oil requirements
6
Generac
®
Power Systems, Inc.
Section 1 – General Information
QUIETPACT 55, 65, and 75 Recreational Vehicle Generators
Figure 1.1 – Connection for 120 Volts Only
Figure 1.2 - Connection for 120/240 Volts
1.6
SPECIFICATIONS
1.6.1 FUEL REQUIREMENTS (GASOLINE)
This generator is equipped with a gasoline fuel system
as standard equipment. Specific installations may pro-
vide either a separate fuel tank for the generator, or the
generator may “share” the vehicle engine’s fuel tank.
1.6.1.1 Fuel Consumption (gph)
NOTE
Some installations using a “shared” fuel tank may
have a generator fuel pickup tube that is shorter
than the vehicle engine’s pickup tube. Such an
arrangement causes the generator engine to “run
out of gas” while adequate fuel for the vehicle
remains in the tank.
To reduce lead and carbon deposits use high quality
UNLEADED gasoline with the generator. Leaded
REGULAR grade gasoline is an acceptable substitute.
NOTE:
Using unleaded gasoline contributes to longer engine
valve life by reducing lead and carbon deposits.
Generac does not recommend using any
gasoline containing alcohol (such as “gasohol”).
If using any gasoline containing alcohol, it must
not contain more than 10 percent ethanol, and
it must be removed from the generator during
storage. Do NOT use any gasoline containing
methanol. If using gasoline with alcohol,
inspect more frequently for fuel leaks and
other abnormalities.
1.6.2 ENGINE OIL REQUIREMENTS
Use only high quality detergent oil rated with
American Petroleum Institued (API) Classification SF,
SG, SH or SJ. The recommended oil viscosity weights
include the following:
• During summer months (40 deg. F and higher),
SAE 30 or SAE 10W-30
• During winter months (40 deg. F to -20 deg. F),
SAE 5W-30 or SAE5W20
• DO NOT USE SAE 10W-40
◆
!
✧
◆
T1
RED
T2
WHITE
T3
BLACK
GROUNDED NEUTRAL
STATOR WINDINGS
CB1
CB2
◆
1.6.3
GENERATOR SPECIFICATIONS
SERIES
QP55G
QP55LP
QP65G
QP65LP
QP75G
QP75LP
Rotor RPM
3600
3600
3600
3600
3600
3600
Rotor Poles
2
2
2
2
2
2
Engine RPM
2200
2200
2571
2571
2571
2571
Rated Max. Continuous AC Output Watts*
5500
5500
6500
6500
7500
7500
Voltage*
120
120
120
120
120
120
Rated Max. Continuous Current Amps (240V)
45.8 (22.9)
45.8 (22.9)
54.1 (27.0)
54.1 (27.0)
62.5 (31.2)
62.5 (31.2)
Phase
1
1
1
1
1
1
Frequency
60 Hertz
60 Hertz
60 Hertz
60 Hertz
60 Hertz
60 Hertz
Battery Charging Current (Max.)
2 amps
2 amps
2 amps
2 amps
2 amps
2 amps
Weight
326 lbs.
329 lbs.
328 lbs.
331 lbs.
330 lbs.
333 lbs.
Length
33.7 in.
33.7 in.
33.7 in.
33.7 in.
33.7 in.
33.7 in.
Width
22.2 in.
22.2 in.
22.2 in.
22.2 in.
22.2 in.
22.2 in.
Height
19.6 in.
19.6 in.
19.6 in.
19.6 in.
19.6 in.
19.6 in.
*
All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output
Model
10% Load
50% Load
100% Load
QuietPact 55G
0.51
0.73
0.97
QuietPact 65G
0.51
0.76
1.07
QuietPact 75G
0.51
0.80
1.28