beautypg.com

9 major service manual, 10 drive belt, 11 exercising the generator – Guardian Technologies 004702-0 User Manual

Page 17: 12 out of service procedure, 13 rv generator service interval

background image

Generac

®

Power Systems, Inc.

15

3.9

MAJOR SERVICE MANUAL

To obtain a service manual for the generator, contact
the nearest Generac Authorized Service Dealer. Make
sure to identify the MODEL NUMBER and SERIES.
Manuals can be obtained from the internet website
(www.generac.com) or a service dealer.

3.10 DRIVE BELT

The engine drives the generator rotor by means of a
pulley and drive belt arrangement. Drive belt tension
was properly adjusted before the unit was shipped
from the factory. If suspect that drive belt tension is
incorrect, contact a Generac Authorized Service
Dealer.

3.11 EXERCISING THE GENERATOR

Generac recommends starting and operating the gen-
erator at least once every seven days. Let the unit run
for at least 30 minutes to “exercise” the engine.

3.12 OUT OF SERVICE PROCEDURE

3.12.1 REMOVAL FROM SERVICE

If the generator cannot be exercised every seven days,
and it is to be out of service longer than 30 days, pre-
pare the generator for storage as follows:

1. Start the engine and let it warm up.
2. Close the fuel shutoff valve in the fuel supply line

and allow the unit to shut down.

3. While the engine is still warm from running,

drain the oil completely. Refill the crankcase with
SAE 5W-30 oil having API classification “For
Service SF.”

4. Attach a tag to the engine indicating the viscosity

and classification of the oil in the crankcase.

5. Remove the spark plug and pour two or three

tablespoons of clean, fresh engine oil into the
spark plug threaded openings. Reinstall and
tighten the spark plug.

6. Remove the battery and store it in a cool, dry

room on a wooden board. Never store the battery
on any concrete or earthen floor.

7. Clean and wipe the entire generator.

3.12.2 RETURN TO SERVICE

To return the unit to service after storage, proceed
as follows:

1. Check the tag on the engine for oil viscosity and

classification. Verify that the correct recommend-
ed oil is used in the engine (see Section 1.5.4). If
necessary, drain and refill with the proper oil.

2. Check the state of the battery. Fill all cells of

unsealed batteries to the proper level with distilled
water. DO NOT USE TAP WATER IN THE BAT-
TERY. Recharge the battery to 100 percent state of
charge, or, if defective, replace the battery.

3. Clean and wipe the entire generator.
4. Reconnect the battery. Observe battery polarity.

Damage may occur if the battery is connected
incorrectly.

5. Turn OFF all electrical loads. Add fuel if neces-

sary and then start the engine.

6. Allow the unit to warm up thoroughly.
7. Apply electrical loads to at least 50 percent of the

unit’s rated wattage capacity.

8. When the engine is thoroughly warmed up, shut

it down.

9. The generator is now ready for service.

3.13 RV GENERATOR SERVICE

INTERVAL

QUIETPACT 55/65/75:

50 Hours ................................Clean Spark Arrestor
1st 50 Hours,

then every 500 Hours ................Adjust Valve Lash

100 Hours..........................Change Engine Oil/Filter
100 Hours ..................................Clean Air Pre-filter
100 Hours ................................Inspect Spark Plugs
250 Hours ............Replace Paper Air Filter Element
400 Hours ..................................Replace Fuel Filter
500 Hours................................Replace Spark Plugs

Section 3 – Maintenance

QUIETPACT 55, 65, and 75 Recreational Vehicle Generators

This manual is related to the following products: